background image

20

MR

The motor can be remotely activated using a transmitter. 
Two functions are available: 
-  sequential command open-block-close-block;
-  activating the C-NO potential free contact (binding posts 7/8). 
The commands can be given from any of the available channels.

S449 SERIES RADIO CONTROLS

Memory module M1

This is an extractable non volatile EEPROM type memory and contains 
the transmitter codes and allows you to memorise up to 

300 codes

 

(300 channel buttons).
The programmed codes are maintained in this module even during 
blackouts. 

s

Attention!

 If the electronic card has to be replaced due to failure, 

the module can be extracted from it and inserted into the new card. 
Make sure that the module is orientated in the direction shown in 

fig. 12

Signal LEDs "L2" (fig. 12)

Flashing quickly: 

cancels a single code

Flashing slowly:  

memorises a single code

Permanently lit:  

memory full.

TRANSMITTER CODE MANAGEMENT

Attention!

 Before memorising the transmitters for the first 

time remember to cancel the entire memory content.

A. Memorising a channel (using the associated transmitter)
B. Cancelling a channel (using the associated transmitter)
C. Cancelling all codes in memory
D.  Memorising ulterior channels via radio (without having to open 

the box in which the receiver is housed)

A) Memorising a channel (fig. 12):

1. Press and hold down button "

P3

MEMO

: The LED "

L2

" will flash 

slowly.

2. At the same time activate the transmitter which is to be memo-

rised.

3. Hold down button "

P3

MEMO

 until LED "

L2

" starts to flash 

again.

4. Release the button: The LED will continue to flash.

5. Activate the transmitter again (same transmitter, same channel; if the 

channel is different or it is a different transmitter the memorisation 
attempt will abort without success).

6. End of memorisation: The LED "

L2

" will remain lit for 2 seconds, 

indicating that the transmitter has been correctly memorised.

Note:

s )TISNOTPOSSIBLETOMEMORISEACODEWHICHISALREADYINMEMORY

if you attempt this, the LED will switch off when you activate the 
transmitter (point 2). 

  Only after releasing the button "

P3

MEMO

 will you be able to 

continue the memorising procedure. 

s )FAFTERACTIVATINGTHETRANSMITTERFORTHElRSTTIMEYOUWAITFORMORE

than fifteen seconds without activating the transmitter a second 
time the memorisation attempt will abort without success.

B) Cancelling a channel (fig. 12):

1. Press and hold down the button "

P4

DEL

: The LED "

L2

" will flash 

quickly.

2. Activate the transmitter channel which is to be cancelled.

3. The LED will remain lit for 2 seconds, indicating that the transmitter 

has been cancelled.

Note:

s )FTHEUSERTHATYOUWISHTOCANCELISNOTINMEMORY4HE,%$WILL

stop flashing; Only after releasing the button "

P4

" will you be able 

to continue the cancellation procedure.

s &OR BOTH THE MEMORISATION AND CANCELLATION PROCEDURES IF THE

button is released before activating the transmitter the procedure 
will abort.

 REMOTE 

CONTROL

C) Cancelling all user codes from memory (fig. 12):

1. Keep both buttons pressed down ("

P3+P4

") for more than four 

seconds

2. LED "

L2

" will remain lit during the entire cancellation time (about 8 

seconds).

3. LED "

L2

" switches off when the cancellation procedure has termi-

nated.

Note:

 When the memory is almost full the time required to search 

for a user code could take up to 1 second from when the command 
was received. If led 

"L2"

 remains alight memory is completely full. 

To memorise a new transmitter you will first have to cancel a code 
from memory.

D) Memorising ulterior channels via radio 

s -EMORISATIONCANBEACTIVATEDBYRADIOWITHOUTOPENINGTHERECEIVER

container) if jumper "

J1

" has been inserted (fig. 12).

1) Make sure that the jumper "

J1

" has been inserted (fig. 12).

2) Using a transmitter, in which at least one channel button "A,B,C 

or D" has already been memorised in 
the receiver, press the button on the 
transmitter as shown in the figure. 

  Note: all the receivers within range 

when the channel button is pressed 
(and which have at least one of the 
transmitter channel buttons memo-
rised) will activate their signal buzzer "

B1

" (fig. 12). 

3) Press one of the channel buttons on the same transmitter. The 

receivers which do not contain that channel code will sound a five-
second long "beep" and will then disactivate. The receivers which 
contain the channel code will sound a one-second long "beep" and 
will enter the "

programming via radio

" mode. 

4) Press the previously chosen channel buttons on the transmitter 

which you wish to memorise; the receiver will sound 2 "beeps" of 
half a second each after which the receiver will be ready to receive 
another code.

5) To leave the programming mode wait for 5 seconds without pressing 

any buttons. The receiver will sound a five-second long "beep" and 
will then exit the programming mode.

s 7HENTHEMEMORYISENTIRELYOCCUPIEDTHEBUZZERWILLSOUNDRAPID

"beeps" and will automatically leave the "

programming via radio

mode. Led "

L2

" will remain lit on the receiver. The same signal is 

given each time you try to enter "

programming via radio

" when 

the memory is full.

s 3ECONDRADIOCHANNELOUTPUT/54#( 

  A normally open contact (

60 VA/24 W 30 Vac-dc

 only resistive 

loads, excluding light bulbs) is available between binding posts 7 
and 8. You can select a channel to associate with this contact using 
jumper "

J2

". 

s #HANNELSELECTION*UMPER* 

In the example "

C

" a four channel transmitter is assigned with the 

following functions:
- channel "

A

" activates the dynamic command ("

TD

")

- channel "

D

" activates the "

OUT CH2

" output 

  (closes the contact between binding posts 7 and 8)

CONNECTING THE ANTENNA

The receiver is supplied with its own antenna which consists of a piece 
of rigid wire 

345 mm

 in length. In alternative it is possible to connect 

an 

ANS400

 tuned antenna using a coaxial cable 

RG58

 (impedance 

50

7

) with a maximum length of 

15 m

.

CHD

CHC

CHB

CHA

CHD

CHC

CHB

CHA

CHA

CHD

Dynamic 

command

 selection

"Out CH2"

Activation 

selection

Channel selection example

CHA: Dynamic command

CHD: CH2 activation

A

B

C

10

Summary of Contents for 101/SL402409

Page 1: ...a programaci n P gina 45 46 Mando v a radio P gina 47 Cargador de bater as opcional P gina 48 Esquema el ctrico est ndar P gina 50 Caracter sticas t cnica P gina 52 ZVL317 05 Mod 30 09 2009 ATTENZIONE...

Page 2: ...Distance entre parties xes et mobiles C Rail de guidage D Distance de s curit E But e en fermeture F l ment lastique d formable G Cl ture H Distance entre cl ture et portail I Grillage ou grille L Pa...

Page 3: ...eur 2 Cellule photo lectrique int rieure 3 Cellule photo lectrique ext rieure 4 S lecteur cl 5 Clignoteur 6 Interrupteur omnipolaire avec ouverture des contacts d au moins 3 mm 7 Bord de s curit 8 Erg...

Page 4: ...ATO ALL INTERNO DELLA PROPRIET ED IL CANCELLO NON DEVE APRIRSI VERSO L AREA PUBBLICA 3 Il cancello motorizzato principalmente adibito al passaggio di vetture Dove possibile installare per pedoni un in...

Page 5: ...raincorrispondenzadellamassima corsa P tale da garantire la stabilit del cancello e quindi di evitare il pericolo di sgancio dalle guide Attenzione COMUNQUE CURA DELLgINSTALLATORE VERIlCARE I PUNTI CR...

Page 6: ...edere al posizionamento dei naselli di necorsa apertura e chiusura montati sulla cremagliera s 0ER UN CORRETTO FUNZIONAMENTO IL CANCELLO devefermarsi dopol interventodel necorsa di chiusura circa 1 cm...

Page 7: ...iera utilizzare cavo con marcatura T min 85 C resistente agli agenti atmosferici s CONDUTTORI DOVRANNO ESSERE ADEGUATAMENTE lSSATI IN PROSSIMIT della morsettiera in modo che tale ssaggio serri sia l i...

Page 8: ...mento con batteria il comando TAL esegue l apertura totale come il TA Nota utilizzandol uscitadelsecondocanaleradio morsetti7e8 pereseguire la funzione di apertura limitata si pu avere il controllo de...

Page 9: ...NTAMENTO I VALORI SELEZIONABILI VANNO DA 2 A 4 SECONDI PREMERE PROG PREMERE SEL 1 20 sec ATTENDERE CIRCA 20 SECONDI SENZA PREMERE NESSUN TASTO IL PROGRAMMATORE SALVA I PARAMETRI FIN QUI IMPOSTATI ED E...

Page 10: ...nei primi secondi del moto in apertura La gestione dei tempi di lavoro permette di controllare la posizione dell anta Quando manca l alimentazione il programmatore a meno che non risulti attivo uno d...

Page 11: ...AZIONAREADISTANZAILMOTORETRAMITERADIOCOMANDO 3ONODISPONIBILI 2 funzioni comando sequenziale apre blocco chiude blocco attivazione di un contatto pulito C NA morsetti 7 e 8 I comandi sono eseguibili in...

Page 12: ...ire la connessione della batteria quindi dare la tensione di rete al motoriduttore AVVERTENZE I liperlaconnessionedellabatteriaalcircuitodicarica non devono essere mai messi in cortocircuito pena il d...

Page 13: ...zards 2 The motor must be installed on the inside of the property and not on the public side of the gate The gate must not open onto a public area 3 Thegateoperatorisdesignedforuseongatesthroughwhichv...

Page 14: ...tion site for electronic and electrical goods or to send it back to the manufacturer if the intention is to replace it with a new equivalent version of the same product Suitable differential collectio...

Page 15: ...n the terminal block while the travel limit common wire Black position 11 remains in the same position Using the MANUAL MODE check the correct functioning of the gate MANUAL RELEASE MECHANISM Manual r...

Page 16: ...AY THAT BOTH THE wire and the insulating sheath are tightly fastened a plastic jubilee clip is suf cient If possible use the supplied cable clamp ELECTRONIC CARD DESCRIPTION g 12 ELECTRONIC PROGRAMMER...

Page 17: ...s after the programmed pause period has elapsed when the opening cycle has been completed or straight away after the inter vention of a photoelectric cell the intervention of a photoelectric cell caus...

Page 18: ...PROG PRESS SEL PRESS SEL Travel limits enabled WAIT FOR ABOUT 20 SECONDS WITHOUT PRESSING ANY BUTTONS THE PROGRAMMER WILL SAVE THE PARAMETERS SET UP TO NOW AND WILL QUIT PROGRAMMING PRESS SEL ALTERNA...

Page 19: ...As each new movement command starts slowly the work time calculation will be false therefore you must reprogram the work times Warning Pressing the SEL button during time programming after having mov...

Page 20: ...ansmitter the procedure will abort REMOTE CONTROL C Cancelling all user codes from memory g 12 1 Keep both buttons pressed down P3 P4 for more than four seconds 2 LED L2 will remain lit during the ent...

Page 21: ...circuit protection fuse F3 10A rapid action The LED L1 on the battery charger will light up when the battery is properly connected The proper procedure is as follows with the power to the motor switc...

Page 22: ...de risque pour la circulation E MOTEUR DOIT TRE INSTALL L INT RIEUR DE LA PROPRI T ET LE PORTAIL NE DOIT PAS S OUVRIR SUR LE DOMAINE PUBLIC 3 Le portail automatis est affect principalement au passage...

Page 23: ...UR AUTANT QUE L APPAREIL SOIT DE TYPE QUIVALENT CELUI QU IL FOURNIT Lacollectes lectivedes quipements lectriqueset lectroniquesenvuedeleur VALORISATION LEURTRAITEMENT ETLEUR LIMINATION DANSLERESPECT D...

Page 24: ...onnement du portail en effectuant quelques man uvres d essai en mode MANUEL D VERROUILLAGE MANUEL Le d verrouillage se fait avec moteur arr t par suite d une coupure de courant Pour d verrouiller le p...

Page 25: ...tion des agents atmosph riques s ES CONDUCTEURS DEVRONT TRE AD QUATEMENT lX S PROXIMIT DU bornier Cette xation devra bloquer tant l isolation que le conducteur il suf t d un collier Si possible utilis...

Page 26: ...ellules photo lectriques durant le temps d arr t l intervention des cellules photo lectriques provoque un reset du temps d arr t Durant le temps d arr t sur l af cheur clignote le symbole Une pression...

Page 27: ...ATEUR SAUVEGARDE LES P 2 42 3 02 2 3 5315g 02 3 4 4 15 44 02 2 TION APPUYER SUR SEL ALTERN S ALTERN S APPUYER SUR SEL APPUYER SUR PROG ALTERN S ALTERN S APPUYER SUR PROG VALEUR FIXE APPUYER SUR SEL AL...

Page 28: ...rtail les premi res secondes de la man uvre d ouverture La gestion des temps de travail permet de contr ler la position du portail En cas de coupure de courant le programmateur moins que l un des ns d...

Page 29: ...ur max de 15 m CHD CHC CHB CHA CHD CHC CHB CHA CHA CHD Il est possible de commander distance le moteur par le biais d une t l com mande radio On dispose de deux fonctions commande s quentielle ouvre a...

Page 30: ...ttre le motor ducteur sous tension de r seau Par contre si le LED L1 ne s allume pas intervertir la connexion de la batterie et mettre ensuite le motor ducteur sous tension de r seau AVERTISSEMENT Les...

Page 31: ...n der Strasse haben so dass sie keine Gefahr f r den Strassenverkehr darstellt 2 Der Motor muss innerhalb des Privatgel ndes installiert werden und das Tor darf sich nicht in Richtung eines ffentliche...

Page 32: ...Tores berpr fen und falls n tig ersetzen und schmieren Nivellierung N der Schiene pr fen die Gleitschuhe oder Rollen der oberen F hrung O sollten ein angemessenes Spiel beim Verschiebung des Tor gels...

Page 33: ...die Kabel der Endanschl ge Rot und Blau Position 12 und 13 der Klemmenreihe umkehren w hrenddergemeinsameLeiterdesEndanschlags Schwarz Position 11 unver ndert bleibt Mehrmals die Funktion des Tors in...

Page 34: ...werden dasssowohldieIsolierungalsauchderLeiter befestigt wird Kabelband gen gt Wo m glich kann die mitgelieferte Kabelschelle verwendet werden BESCHREIBUNG ELEKTRONISCHE PLATINE Abb 12 ELEKTRONISCHE S...

Page 35: ...endigung des ffnungsvorgangs oder ab dem Augenblick in dem die Lichtschranken zum letzten Mal w hrend der Pausenzeit intervenieren die Intervention der Lichtschranken verursacht ein Zur cksetzen der P...

Page 36: ...EN WAHL 3 SEKUNDEN WAHL 4 SEKUNDEN DIE TASTE PROG F R MEHR ALS 4 SEKUNDEN GEDR CKT HALTEN ES ERSCHEINT DER BUCHSTABE d DER F R DEFINITION DER SYSTEMPARAMETER PHASE A STEHT NACH 1 SEKUNDE ERSCHEINT DIE...

Page 37: ...zeit verf lscht und die Programmierung muss wiederholt werden Achtung Die Bet tigung der Taste SEL in der Programmier phasederZeiten nachBewegungdesT r gels verhindertdie korrekte Vervollst ndigung de...

Page 38: ...P3 P4 l nger als 4 Sekunden gedr ckt halten 2 DieLED L2 leuchtetw hrenddergesamtenZeitdesL schvorgangs ca 8 Sekunden 3 Die LED L2 erlischt der L schvorgang ist abgeschlossen Hinweis WennderSpeicherde...

Page 39: ...ie LED L1 au euchtet bedeutet dies dass der Anschluss richtig ist und dass der Untersetzungsmotor mit Netzstrom versorgt werden kann Falls die LED L1 nicht au euchtet den Anschluss der Batterie umklem...

Page 40: ...n 2 El motor debe instalarse en el interior de la propiedad y la cancilla no debe ABRIRSE HACIA EL REA P BLICA 3 La cancilla motorizada est principalmente destinada al paso de veh culos Donde sea pos...

Page 41: ...seventuales desgastadasdelacancela y de ser necesario proceder a sustituirlas y lubricarlas Comprobar la puesta a nivel N de la gu a Los patines o rodillos de gu a superiores O deben tener el juego co...

Page 42: ...DEL MICROINTERRUPTOR DE TOPE EGRO POSICI N 11 queda en su sitio Comprobar mediante algunas maniobras en la modalidad MANUAL el funcionamiento correcto de la cancela INSTRUCCIONES PARA LA COLOCACION D...

Page 43: ...BEN lJAR DEBIDAMENTE CERCA DE LA BORNERA DE modoquesu jaci nincluyatantoelaislamientocomoelconductor es su cienteunaabrazadera Aserposible sepuedeutilizarelprensahilo suministrado PROGRAMADOR ELECTRON...

Page 44: ...namiento con bater a el mando TALv EFECT A LA APERTURA total como el TA s Nota utilizando la salida del segundo canal de radio bornes 7 8 para efec tuar la funci n de apertura limitada se puede tener...

Page 45: ...4 SEGUNDOS PULSAR PROG PULSAR SEL 1 20 seg ESPERAR UNOS 20 SEGUNDOS SIN PULSAR NINGUNA TECLA EL PROGRAMADOR GUARDA LAS ENTRADAS QUE HAN SIDO FIJADAS HASTA ESTE MOMENTO Y SALE DE LA PROGRAMACI N PULSAR...

Page 46: ...r lo cual se debe volver a empezar una nueva programaci n Cuidado Al oprimir la tecla SEL durante la fase de pro gramaci n de los tiempos se impide la nalizaci n correcta del procedimiento Cuidado Pro...

Page 47: ...diatamente de la modalidad MR MANDO VIA RADIO CHD CHC CHB CHA CHD CHC CHB CHA CHA CHD A B C 10 C Borrado total de la memoria de usuarios g 12 1 Mantener pulsados ambos botones P3 P4 durante algo m s d...

Page 48: ...oto L1 no se enciende invertir la conexi n de la bater a y luego suministrar tensi n de red al motorreductor ADVERTENCIAS Loscablesparalaconexi ndelabater aconelcircuito DECARGANOSEDEBENPONERNUNCAENCO...

Page 49: ...49 NOTES...

Page 50: ...NA FTC RX 1 3 2 24V 12V 0 FTC TX 1 2 PS NC NA J1 J1 9 10 11 12 15 16 17 18 13 14 19 20 TD TB LS 24V FCC FCA FTC_I FTC_S TC TA TAL CMN 1 2 3 4 5 6 7 8 LP 24V OUT 24V OUT CH2 CMN CMN CMN CMN ANS400 SCH...

Page 51: ...Elettromagnetica Direttiva 73 23 CEE Bassa Tensione San Vendemiano il 16 10 2008 Ing A Fiorotto Design engineer R D Laboratory x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x...

Page 52: ...4 Number of functions N 2 Number of memorisable codes N 300 Alimentation Vac 230 Fr quence Hz 50 Courant nominal A 0 6 Puissance absorb e W 120 Intermittence de travail 100 Vitesse d entra nement m mi...