background image

Instruction Manual for the  

Manufactured by 

Heavy Duty Series  

Carriage Door Instructions 

Summary of Contents for Estate Swing Heavy Duty Series

Page 1: ...Instruction Manual for the Manufactured by Heavy Duty Series Carriage Door Instructions...

Page 2: ...9 The installation must conform to Standards EN 12453 and EN 12445 The safety level of the automated system must be C D 10 Before attempting any job on the system cut out electrical power and disconne...

Page 3: ...in length It consists of an irreversible electro mechanical operator with guard and an articulated arm activation system to be fitted to the door with the appropriate accessories The irreversible syst...

Page 4: ...for Installation 1 3 Operator Basics 2 Manual Operation Restoring Automation 2 1 Installation 3 Mounting Position 3 1 Installation of operator 3 2 3 Pre Programming 4 Mounting the Control Board and B...

Page 5: ...your door opener The table of contents are listed to assist you locating a desired section We do how ever strongly suggest studying every page of the instruction manual before attempt ing installatio...

Page 6: ...4 to 131 Deg F Gearmotor weight lbs 25 Protection class IP44 Door leaf max length ft Up to 8 Door leaf max weight lbs Up to 800 Operator overall dimensions LxHxD in See below Angular velocity 8 Degre...

Page 7: ...et 10 Control Box 11 Control Board 12 Transmitter 13 Receiver 14 Transformer 15 Control Box Screws Control Board Screws and Washers Jumper Wire Master Operator 1 Housing Cover 2 Wall Mounting Plate 3...

Page 8: ...nect the Base Plate to the wall Length and style will be determined by what is needed for a secure anchor for your mate rial door 2 5 16 fasteners will be needed to connect the Door Mounting Bracket t...

Page 9: ...kwise to lock To avoid an involuntary pulse activating the doors during the maneuver before re locking the operator switch off all power Fit the supplied Allen wrench and turn it by approximately a ha...

Page 10: ...on the mounting plate above the door frame with the release just inside the frame the door frame The drive shaft piece that comes down from the motor that makes the arm pivot should be positioned insi...

Page 11: ...roper position for your operator from previous page Mark the outline of the base plate with the operator in the correct position Then remove the mo tor from the base plate 2 Secure the base plate to t...

Page 12: ...operator From section 2 7 Find securing point B from the mounting set back determined from the previous page Verify the arm is level then temporarily remove the coupling from the arm in order to atta...

Page 13: ...ol box The knock outs are multi sized purchase water tight connectors to run the wires into the box The water tight connectors go in the knockouts on the bottom 3 To mount the control board first moun...

Page 14: ...terminal strips on the control board are easily removed for wiring Simply pull straight out on the terminal strip to remove it from the board It will slide right off Slide it back on when you are fin...

Page 15: ...u must be on operating parameter Mounting the limit switches Slide the limit rings on the top side of the transmission shaft Line up the holes on the limit switches with the holes on the top of the op...

Page 16: ...t Connection 4 is not used Example of how to tighten the limit ring Terminal Block CN3 COMF Common from all limit switches FCC1 Jump to COMF FCA1 N C Limit Connection Open Door Limit Switch on Master...

Page 17: ...ping these terminals to common COM during the set up process It is recommended not to use any accessories until setup and programming are complete NOTE If not using safety devices the temporary safety...

Page 18: ...block CN2 insert the BROWN wire in APM2 and BLUE wire in CHM2 During the learning process if the door begins to move in the wrong direction Stop the door operator by removing power or tripping RESET s...

Page 19: ...the receiver wire 3 Using a 6 screw attached the top of the receiver to the post If you are happy with this position use the small provided set screw in the bottom hole to secure the receiver in plac...

Page 20: ...ld mean 1 button on 400 different remotes or this could mean all 4 buttons on 100 remotes or anything in between Some choose to program all 4 buttons to a single receiver if they are not using multipl...

Page 21: ...mer plugged in Contact between the two lead wires even for a second will destroy the transformer 3 Plug the transformer into a 110 V AC outlet 4 The transformer is not weather proof and must be kept i...

Page 22: ...3 Press and hold down P2 until the display shows parameter A with the corresponding number that is currently default or previously pro grammed 4 Press P1 to change the number variable of the paramete...

Page 23: ...fety This parameter turns auto close on or off The pause time for the auto close is set during movement programming OPEN A Opens Closes Opens Opens Stops Closes Stops This parameter determines what an...

Page 24: ...SOFT SPEED Parameter must be on 0 No Limit Switch Limit Switch LIMIT SWITCH Parameter must be on L0 Single Leaf Door Dual Leaf Door SINGLE OR DUAL For carriage doors set to n2 After programming your...

Page 25: ...shows the A parameter and the relevant number appear in the LED display 4 Give an OPEN A command This can be done with any opening device keypad push button etc wired into OPEN A and COM or using the...

Page 26: ...doors will stop 7 Once they stop in the open position signal your opener using an OPEN A contact or transmitter signal to close the doors The doors will then re turn to closed and programming will be...

Page 27: ...ped FCC 2 Motor 2 closing limit switch not tripped Motor 2 closing limit switch tripped FCA2 Motor 2 opening limit switch not tripped Motor 2 opening limit switch tripped STOP Stop command not activat...

Page 28: ...et and stops or reverses directions Check dip switches to the left of the LED display It should be 1 OFF 2 OFF 3 ON 4 On If the dip switches are wrong you must turn all power off before changing the d...

Page 29: ...hand to possible range Do not let the arm reach its physical limitations before the stops during normal operation If arms can t extend full expected range check the setback If the opener arm has the p...

Page 30: ...to e mail digital photos to the technician This is done in your best interest to save unnecessary shipping expenses and time lost Many times we can come up with solutions to issues by seeing pictures...

Page 31: ...Input terminals for the optional backup batteries The battery power coming in must be 24V DC This can be achieved by running two 12V batteries Max 5 a h per battery in series During normal operation...

Page 32: ...Slave Closed Limit Switch FCA2 Normally closed contact This terminal is connected with the COMF through the limit switch When tripped connection opened it stops the motion of the second operator If n...

Page 33: ...door opener to be active this cir cuit must be closed When a device opens this circuit it stops the motion of the door operator This circuit is the main circuit for safety devices i e photo eyes safe...