5. When the closing stop point or limit switch is reached, the motor pauses for approximately 2
seconds, and then restarts with a total opening maneuver to the opening stop point or limit
switch.
6. When the full open stop or limit switch is
reached the doors will stop.
7. Once they stop in the open position signal your
opener using an OPEN A contact or transmitter
signal to close the doors. The doors will then re-
turn to closed and programming will be complete.
If you decide to use auto-reclose (not recommended)
after the doors reach the full
open wait for the amount of time you would like your doors to pause for during normal opera-
tion before automatically re-closing and then complete step 7.
5.5