Operating Parameters Chart
Minimum Force
Medium-low Force
Medium-high Force
High Force
This parameter adjusts the sensitivity of the
electronic clutch system. The electronic clutch
system controls the anti-crushing auto-reverse
feature when a door in motion makes contact
with an obstacle.
1.5 Second Offset
3 Second Offset
6 Second Offset
10 Second Offset
This determines how long the second leaf will
pause before moving to allow the first leaf to
separate and avoid obstructing on the other
leaf.
Disabled
Enabled
c0 recommended for safety.
This parameter
turns auto-close on or off.
The pause time for the
auto-close is set during movement programming.
OPEN
A
Opens/Closes/Opens...
Opens/Stops/Closes/Stops...
This parameter determines what an OPEN A
terminal command will result in.
d1 is recom-
mended for safety.
Disabled
Enabled
E0 recommended for safety.
This parameter
is for use with multiple door users. If enabled,
when the door is opening it can not be re-
versed by another open signal.
FORCE
DELAY
AUTO-
RECLOSE
CONDO
Disabled
Enabled
OVER-
PUSH
F0 required for carriage doors.
Flashing Lamp
90 Second Courtesy Light
LAMP
This parameter is to determine between a
flashing or steady lamp. If not using a lamp the
setting will not affect your door.
Continued on following page.
5.2