187
16. Example of Host Control Sequence
16.1 Assignment of Host Control Mode
In case of VC-C50i controlled by host, Necessary to change VC-C50i control mode.
By local control mode flag (bit 18) of operation status, the current mode can be found
host control mode or local control mode.
Host
VC-C50i
Power ON
Control Mode Change
CTS ON
RTS ON
(1) System Control Command
Extended Operation Status Request
(2) Answer (ACK + Status)
(3) System Control Command
Host Control Mode
(4)
Answer
(ACK)
(5) System Control Command
Extended Operation Status Request
(6) Answer (ACK + Status)
Corresponding Frame Code
Command/Answer
(1)
FF 30 30 00 86 30 EF
(2)
FE 30 30 30 30 37 30 30 31 30 EF
(3)
FF 30 30 00 90 30 EF
(4)
FE 30 30 30 30 EF
(5)
FF 30 30 00 86 30 EF
(6)
FE 30 30 30 30 33 30 30 3130 EF