45
12.20 Pan Maximum Angle Request
Pedestal Control Command Type 1
Function
To return the maximum value (right) in Pan direction.
Command 005Ch
Length 1
byte
Parameter
Value 1h
Length 4
byte
Normal Mounting: +889 (8379h)
Status
Value
Inverse Mounting: +1511 (85E7h)
Reference •Status Value (+889) in normal mounting is the position rotated approx.
100 degree to right as zero degree for front.
•Status Value (+1511) in inverse mounting is the position rotated approx.
170 degrees to right as zero degree for front.
Format of Control Code
d0 d1 d2 d3 d4 d5 d6
Header
Device Num
Command
Parameter End mark
FFh 30h 3Xh 00h 5Ch 31h EFh
Answer Format
In case of No Error
d0 d1 d2 d3 d4 d5 d6 d7 d8 d9
Header
Device Num
Error Code
Status
End mark
FEh 30h 3Xh 30h 30h 38h 33h 37h 39h EFh
or
d0 d1 d2 d3 d4 d5 d6 d7 d8 d9
Header
Device Num
Error Code
Status
End mark
FEh 30h 3Xh 30h 30h 38h 35h 46h 37h EFh
In case of Error
d0 d1 d2 d3 d4 d5
Header
Device Num
Error Code
End mark
FEh 30h 3Xh e0 e1 EFh
⇓
Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of Parameter Error :
01010000B
⇒
50h
⇒
35h 30h
In case of Mode Error :
10010000B
⇒
90h
⇒
39h 30h
Condition of Error flag to be set
Parameter Error •Assign illegal parameters.
Mode Error
•Not in status of
Camera ON.
•Not in status of