165
14.31
Screen
Control
System Control Command Type 1
Function
To control screen display of date, time, characters.
Command 0091h
Length 2
byte
Parameter
Range 00h~09h
Status None
Reference •The following display indication can be set,
Parameter
00h : Display Indication OFF
(Screen Display OFF)
01h : Display Indication ON
(Screen Display ON)
02h : Character Indication OFF
03h : Character Indication ON
04h : Time Indication OFF
05h : Time Indication ON 1
(Indication Format 1)
06h : Time Indication ON 2
(Indication Format 2)
07h : Date Indication OFF
08h : Date Indication ON 1
(Indication Format 1)
09h : Date Indication ON 2
(Indication Format 2)
•At the moment of power ON, display indication OFF, character indication
ON, time indication ON2, date indication ON2 are set by default.
•By display indication ON/OFF control, all function able to be controlled,
even though each of character indication, time indication, date indication is
set ON/OFF.
•Time Indication Format has two type as under,
Indication Format 1
hh :
mm : ss
Indication Format 2
HH :
mm : ss AP
hh
⇒
Hour (00~24)
HH
⇒
Hour (00~12)
mm
⇒
Minute (00~59)
ss
⇒
Second (00~59)
AP
⇒
AM or PM
•Date Indication Format has two type as under,
Indication Format 1
yy : mm : dd
Indication Format 2
dd : MM : yy
yy
⇒
Year (00~99)
mm
⇒
Month (01~12)
MM
⇒
Month (JAN, FEB, MAR, APL, MAY, JUN,
JUL, AUG, SEP, OCT, NOV, DEC)
dd
⇒
Date (01~31)
Note:
At the moment of power ON, time indication & date indication start flashing