88
13.27 AE Lock OFF
Camera
Control
Command
Type
1
Function
To cancel AE Lock ON status.
Command
00A5h
Length
2 byte
Parameter
Value
40h
Status
None
Reference •To set auto exposure mode ON.
•Default value is set at the moment of executing
Camera Reset
and
Camera
ON
command during power ON.
Format of Control Code
d0 d1 d2 d3 d4
d5 d6 d7
Header
Device Num
Command
Parameter
End mark
FFh 30h 3Xh 00h A5h 34h
30h EFh
Answer Format
d0 d1 d2 d3 d4 d5
Header
Device Num
Error Code
End mark
FEh 30h 3Xh e0 e1 EFh
⇓
Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error :
00000000B
⇒
00h
⇒
30h 30h
In case of Busy :
00010000B
⇒
10h
⇒
31h 30h
In case of Mode Error :
10010000B
⇒
90h
⇒
39h 30h
Condition of Error flag to be set
Busy
•In process of camera initializing operation by
Camera Reset
command, etc.
•In status of exposure mode manual.
•In case of executing
Preset Move
command.
Mode Error
•Not in status of
Camera ON.
•Not in status of
Host Control Mode.