177
14.40 Command Termination Notification Setting
System Control Command Type 1
Function
To set command termination notification ON/OFF after command type 2
completion.
Command
0094h
Length 1
byte
0h: OFF (not Notify)
Parameter
Value
1h: ON (Notify)
Status
None
Reference •At the moment of power ON, to OFF by default.
•Command termination notification comes out to effective at the command
after issuing this command.
•See
Communication Timing Diagram
(
3.3
),
Function of Command
Termination Notification (6)
,
Classification by Execution Format (10.2)
.
Format of Control Code
d0 d1 d2 d3 d4 d5
d6
Header
Device Num
Command
Parameter
End mark
FFh 30h 3Xh 00h 94h p0
EFh
⇓
Command termination notification ON/OFF indicates in ASCII code 1 byte.
Example: to notify command termination notification
p0
01h
⇒
31h
Answer Format
d0 d1 d2 d3 d4 d5
Header
Device Num
Error Code
End mark
FEh 30h 3Xh e0 e1 EFh
⇓
Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
In case of No Error :
00000000B
⇒
00h
⇒
30h 30h
In case of Parameter Error :
01010000B
⇒
50h
⇒
35h 30h
In case of Mode Error :
10010000B
⇒
90h
⇒
39h 30h
Condition of Error flag to be set
Parameter Error •In case of assigned parameter except 0h or 1h.
Mode Error
•Not in status of
Camera ON.
•Not in status of