Expand Serial Command Specification
Page 33 of 46
9.4.4. CR_TINT Command
Command “CR_TINT” [CR]
Details
Read Tint value of user control
Acceptable
“000_%1” [CR]
%1
“000” ~ “063”
Response
Unacceptable “Error Code” [CR] --- Invalid
“?” [CR] ----------------- When receives unclear Command
9.4.5. CR_SHARP Command
Command “CR_SHARP” [CR]
Details
Read Sharpness value of user control
Acceptable
“000_%1” [CR]
%1
“000” ~ “031”
Response
Unacceptable “?” [CR]
9.4.6. CR_GAMMA Command
Command “CR_GAMMA” [CR]
Details
Read Gamma value of user control
Acceptable
“000_%1” [CR]
%1
“000” ~ “015”
Response
Unacceptable “?” [CR]
9.4.7. CR_WBAL-R Command
Command “CR_WBAL-R” [CR]
Details
Read White Balance Red value of user control
Acceptable
“000_%1” [CR]
%1
“000” ~ “063”
Response
Unacceptable “?” [CR]
9.4.8. CR_WBAL-G Command
Command “CR_WBAL-G” [CR]
Details
Read White Balance Green value of user control
Acceptable
“000_%1” [CR]
%1
“000” ~ “063”
Response
Unacceptable “?” [CR]
9.4.9. CR_WBAL-B Command
Command “CR_WBAL-B” [CR]
Details
Read White Balance Blue value of user control
Acceptable
“000_%1” [CR]
%1
“000” ~ “063”
Response
Unacceptable “?” [CR]