Expand Serial Command Specification
Page 36 of 46
9.5.4. CR_H-POS Command
Command “CR_H-POS” [CR]
Details
Read Horizontal Position value
Acceptable
“000_%1” [CR]
%1
“0000” ~ “nnnn”
(nnnn = Total Dots – Display Dots)
Response
Unacceptable “Error Code” [CR] --- Invalid
“?” [CR] ----------------- When receives unclear Command
9.5.5. CR_V-POS Command
Command “CR_V-POS” [CR]
Details
Read Vertical Position value
Acceptable
“000_%1” [CR]
%1
“0000” ~ “nnnn”
(nnnn = Total Line – Display Line)
Response
Unacceptable “Error Code” [CR] --- Invalid
“?” [CR] ----------------- When receives unclear Command
9.5.6. CR_DDOTS Command
Command “CR_DDOTS” [CR]
Details
Read Display Dots value
Acceptable
“000_%1” [CR]
%1
“0000” ~ “nnnn”
(nnnn = Total Dots – Horizontal Position)
Response
Unacceptable “Error Code” [CR] --- Invalid
“?” [CR] ----------------- When receives unclear Command
9.5.7. CR_DLINE Command
Command “CR_DLINE” [CR]
Details
Read Display Line value
Acceptable
“000_%1” [CR]
%1
“0100” ~ “nnnn”
(nnnn = Total Line – Vertical Position)
Response
Unacceptable “Error Code” [CR] --- Invalid
“?” [CR] ----------------- When receives unclear Command
9.5.8. CR_ORGMODE Command
Command “CR_ORGMODE” [CR]
Details
Read signal for Mode in PC Adjust
When Mode1 - Mode5 or EXT6 - EXT60 are not selected, read current signal.
Acceptable
“000_%1” [CR]
%1
“XGA1”
“HDTV1080” … Etc.
Response
Unacceptable “?” [CR]