9.12. Other Status Read Command
9.12.1. CR_SIGNAL Command
Command “CR_SIGNAL” [CR]
Details
Read information if there is signal or not
Acceptable
“000_%1” [CR]
%1
“ON” -------- There is signal
“OFF” ------- No signal
Response
Unacceptable “?” [CR]
9.12.2. CR_VMUTE Command
Command “CR_VMUTE” [CR]
Details
Read No Show setting status
Acceptable
“000_%1” [CR]
%1
“ON” ---------- Selected No Show
“OFF” --------- Canceled No Show
Response
Unacceptable “?” [CR]
9.12.3. CR_FREEZE Command
Command “CR_FREEZE” [CR]
Details
Read Freeze setting status
Acceptable
“000_%1” [CR]
%1
“ON” --------- Selected Freeze
“OFF” -------- Canceled Freeze
Response
Unacceptable “?” [CR]
9.12.4. CR_PTIMER Command
Command “CR_PTIMER” [CR]
Details
Read Presentation Timer status
Acceptable
“000_%1” [CR]
%1
“ON” ----------- Presentation timer is active
“STOP” ------- Presentation timer is pause
“OFF” --------- Presentation timer is inactive
Response
Unacceptable “?” [CR]
9.12.5. CR_INFPFAIL Command
Command “CR_INFPFAIL” [CR]
Details
Read the power failure status.
Data is shown in 32bits HEX
Normal = All Hi (FF)
Abnormal = All Lo (00)
Acceptable
“000_%1” [CR]
%1
“********”
Show 32bits hexadecimal numeral in 8 figures
:
“FFFFFFFF” = All are normal
Response
Unacceptable “?” [CR]