![background image](http://html1.mh-extra.com/html/canon/imageformula-dr-9080c/imageformula-dr-9080c_service-manual_4188138092.webp)
3 - 10
COPYRIGHT © 2003 CANON ELECTRONICS INC. CANON DR-6080/9080C FIRST EDITION OCT. 2003
CHAPTER 3 DISASSEMBLY & REASSEMBLY
3) Unfasten the clamp
fixing a cable
that
are pulled out from the right-side of the upper
unit, and unhook four connectors
on the
main CPU PCB.
Cable
Clamp
Connector
Fig. 3-127
4) First, remove one screw
and then the
stopper
.
Remove two screws (with round-shaped tips)
and dismount the damper (black)
.
Remove the additional two screws
, detach
the pivot
, and then finally detach the upper
unit
so as not to damage the cable
.
Note:
Detach the upper unit while holding it to
prevent it from falling.
Screw
Stopper
Screw
Damper
Screw
Pivot
Cable
Upper unit
Fig. 3-128