![background image](http://html1.mh-extra.com/html/canon/imageformula-dr-9080c/imageformula-dr-9080c_service-manual_4188138115.webp)
COPYRIGHT © 2003 CANON ELECTRONICS INC. CANON DR-6080/9080C FIRST EDITION OCT. 2003
3 - 33
CHAPTER 3 DISASSEMBLY & REASSEMBLY
14. Delivery drive roller
1) Detach the right/left cover assembly and top
cover.
2) Let the left belt loosen. Refer to the "Left belt"
section.
3) Unfasten two E-rings (one on each side)
,
detach the pulley
and the pin
.
Additionally, remove two bearings
(one on
each side) and detach the delivery drive roller
.
E-ring
Pulley
Pin
Bearing
Delivery drive roller
Fig. 3-328
15. Right belt
1) Remove the right cover assembly.
2) Loosen four screws
of the main motor
mount plate
and detach the belt
.
Main motor mount plate
Screw
Belt
Fig. 3-329
Precautions during assembly
•
Do not allow any slack in the belt. Adjust the
tension so that the belt does not miss the
sprockets and the tension is not tightened too
much.
Summary of Contents for ImageFormula DR-9080C
Page 4: ......
Page 22: ......
Page 182: ......
Page 188: ...1003N0 0 1...
Page 195: ...COPYRIGHT 2003 CANON ELECTRONICS INC CANON DR 6080 9080C FIRST EDITION OCT 2003 vii...
Page 236: ......
Page 240: ......
Page 242: ...ix 1003N0 0 0...
Page 284: ...38 Chapter 3 Software Closing CapturePerfect 1 Select Exit from the File menu...
Page 308: ......
Page 352: ...1 Imprinter for DR 6080 9080C Installation Procedure IMS Product Planning Dept...
Page 355: ...4 3 Remove the left cover 4 screws Remove these screws x4...
Page 359: ...8 7 Insert it firmly to the back and fix it with 1 screw M3x6...
Page 366: ...15 14 Replace the cable to cable clamp and the document eject cover to the original position...