CHAPTER 3 DISASSEMBLY & REASSEMBLY
7. Ultrasonic sensor PCB (lower side)
1) Detach the right/left cover assembly.
2) Unhook the connector on the main CPU PCB,
which is connected to the cable
. Remove
two screws
(one on each side).
Cable
Screw
Fig. 3-511
3) Pull off the ultrasonic sensor PCB (with metal
plates)
from the right.
Ultrasonic sensor PCB (with metal plates)
Fig. 3-512
Precautions during the assembly
•
Match the positioning marks
on the right
side, tighten the right-side screw while holding
the left side, and then tighten the screw on the
left side.
Positioning mark
Fig. 3-513