![Campbell CR23X Operator'S Manual Download Page 95](http://html1.mh-extra.com/html/campbell/cr23x/cr23x_operators-manual_489029095.webp)
SECTION 7. MEASUREMENT PROGRAMMING EXAMPLES
7-7
The multiplier used in Instruction 7 is determined
in the same manner as in Section 7.8. In this
example, the multiplier (R
f
/R
0
) is assumed to be
100.93.
The 3 wire half bridge compensates for lead wire
resistance by assuming that the resistance of
wire A is the same as the resistance of wire B.
The maximum difference expected in wire
resistance is 2%, but is more likely to be on the
order of 1%. The resistance of R
s
calculated
with Instruction 7, is actually R
s
plus the
difference in resistance of wires A and B. The
average resistance of 22 AWG wire is 16.5
ohms per 1000 feet, which would give each 500
foot lead wire a nominal resistance of 8.3 ohms.
Two percent of 8.3 ohms is 0.17 ohms.
Assuming that the greater resistance is in wire B,
the resistance measured for the PRT (R
0
=
100 ohms) in the ice bath would be 100.17
ohms, and the resistance at 40
o
C would be
115.71. The measured ratio R
s
/R
0
is 1.1551;
the actual ratio is 115.54/100 = 1.1554. The
temperature computed by Instruction 16 from
the measured ratio would be about 0.1
o
C lower
than the actual temperature of the PRT. This
source of error does not exist in the example in
Section 7.8, where a 4 wire half bridge is used to
measure PRT resistance.
The advantages of the 3 wire half bridge are that
it only requires 3 lead wires going to the sensor
and takes 2 single- ended input channels,
whereas the 4 wire half bridge requires 4 wires
and 2 differential channels.
A terminal input module (Model 3WHB10K) can
be used to complete the circuit in Figure 7.9-1. It
uses a
±
0.01%
±
8 ppm precision resistor.
PROGRAM
1: 3W Half Bridge (P7)
1:
1
Reps
2:
22
50 mV, 60 Hz Reject, Slow
Range
3:
1
SE Channel
4:
1
Excite all reps w/Exchan 1
5:
4300
mV Excitation
6:
1
Loc [ Rs_Ro ]
7:
100.93
Mult
8:
0.0
Offset
2: Temperature RTD (P16)
1:
1
Reps
2:
1
R/R0 Loc [ Rs_Ro ]
3:
2
Loc [ TEMP_degC ]
4:
1.0
Mult
5:
0.0
Offset
7.10 100 OHM PRT IN 4 WIRE FULL
BRIDGE
This example describes obtaining the
temperature from a 100 ohm PRT in a 4 wire
full bridge (Instruction 6). The temperature
being measured is in a constant temperature
bath and is to be used as the input for a control
algorithm. The PRT in this case does not
adhere to the DIN standard (alpha = 0.00385)
used in the temperature calculating Instruction
16. Alpha is defined as (R
100
/R
0
-1)/100, where
R
100
and R
0
are the resistances of the PRT at
100
o
C and 0
o
C, respectively. In this PRT,
alpha is equal to 0.00392.
CR23X
FIGURE 7.10-1. Full Bridge Schematic for
100 ohm PRT
The result (X) given by Instruction 6 is 1000
V
s
/V
x
(where V
s
is the measured bridge output
voltage, and V
x
is the excitation voltage) which
is:
X = 1000 (R
s
/(R
s
+R
1
)-R
3
/(R
2
+R
3
))
The resistance of the PRT (R
s
) is calculated
with the Bridge Transform Instruction 59:
R
s
= R
1
X'/(1-X')
Where
X' = X/1000 + R
3
/(R
2
+R
3
)
Thus, to obtain the value R
s
/R
0
, (R
0
= R
s
@
0
o
C) for the temperature calculating Instruction
16, the multiplier and offset used in Instruction 6
are 0.001 and R
3
/(R
2
+R
3
), respectively. The
multiplier used in Instruction 59 to obtain R
s
/R
0
is R
1
/R
0
(5000/100 = 50).
Summary of Contents for CR23X
Page 8: ...CR23X TABLE OF CONTENTS vi This is a blank page ...
Page 12: ...CR23X MICROLOGGER OVERVIEW OV 2 1 2 3 A 4 5 6 B 7 8 9 C 0 D FIGURE OV1 1 CR23X Micrologger ...
Page 34: ...CR23X MICROLOGGER OVERVIEW OV 24 This is a blank page ...
Page 50: ...SECTION 1 FUNCTIONAL MODES 1 16 This is a blank page ...
Page 72: ...SECTION 4 EXTERNAL STORAGE PERIPHERALS 4 8 This is a blank page ...
Page 88: ...SECTION 6 9 PIN SERIAL INPUT OUTPUT 6 10 This is a blank page ...
Page 110: ...SECTION 7 MEASUREMENT PROGRAMMING EXAMPLES 7 22 This is a blank page ...
Page 134: ...SECTION 8 PROCESSING AND PROGRAM CONTROL EXAMPLES 8 24 This is a blank page ...
Page 164: ...SECTION 9 INPUT OUTPUT INSTRUCTIONS 9 30 This is a blankpage ...
Page 188: ...SECTION 11 OUTPUT PROCESSING INSTRUCTIONS 11 8 This is a blankp age ...
Page 221: ...SECTION 13 CR23X MEASUREMENTS 13 21 FIGURE 13 5 1 Circuits Used with Instructions 4 9 ...
Page 229: ...14 3 1 2 3 A 4 5 6 B 7 8 9 C 0 D FIGURE 14 3 1 CR23X Battery Pack and Panel ...
Page 240: ...SECTION 14 INSTALLATION AND MAINTENANCE 14 14 This is a blank page ...
Page 244: ...APPENDIX A GLOSSARY A 4 This is a blank page ...
Page 268: ...APPENDIX B CONTROL PORT SERIAL I O INSTRUCTION 15 B 24 This is a blank page ...
Page 276: ...APPENDIX C BINARY TELECOMMUNICATIONS C 8 This is a blank page ...
Page 278: ...This is a blank page ...
Page 282: ...APPENDIX F DYNAGAGE SAP FLOW P67 F 4 This is a blank page ...
Page 299: ...APPENDIX I TD OPERATING SYSTEM ADDENDUM FOR CR510 CR10X AND CR23X MANUALS ...
Page 300: ...This is a blank page ...
Page 302: ...This is a blank page ...
Page 308: ...TABLE DATA ADDENDUM AD 6 This is a blank page ...
Page 324: ...TD ADDENDUM SECTION 1 FUNCTIONAL MODES AD 1 8 This is a blank page ...
Page 340: ...TD ADDENDUM SECTION 8 PROCESSING AND PROGRAM CONTROL EXAMPLES AD 8 10 This is a blank page ...
Page 342: ...This is a blank page ...
Page 373: ...This is a blank page ...