Section 12. Program Control Instructions
12-6
desirable to delay execution of subsequent instructions if those instructions
perform further processing on the response from the remote.
Security
Enter the level 2 security code for the remote datalogger in the PakBus network
that will be communicated with using this instruction when Command 22 is
used for parameter 3 (send input location data to another datalogger).
If the security code in this instruction does not match the security code of the
remote datalogger, the remote datalogger will discard the message, and the
failure will be indicated in the local datalogger by an incremental change in the
Result Code Location (parameter 8).
If security is not set in the remote datalogger or if command 21 is used for
parameter 3, this parameter can be left at 0.
For additional information on security codes, see Program Security.
Enter the level 2 security code for the remote datalogger in the PakBus network
that will be communicated with using this instruction when Command 22 is
used for parameter 3 (send input location data to another datalogger).
If the security code in this instruction does not match the security code of the
remote datalogger, the remote datalogger will discard the message, and the
failure will be indicated in the local datalogger by an incremental change in the
Result Code Location (parameter 8).
If security is not set in the remote datalogger or if command 21 is used for
parameter 3, this parameter can be left at 0.
Remote Location/Coil/Register
PakBus Communication
If data is being received from another datalogger in the PakBus network
(Parameter 3 set to 21), this is the first input location in the remote datalogger
from which to retrieve the data.
If data is being sent to another datalogger in the PakBus network (Parameter 3
set to 22), this is the first input location in the remote datalogger in which to
store the first data value.
If a variable in the Public (or Input Locations) table is being accessed using Get
Value or Set Value (Parameter 3 set to 26 or 27), this parameter is left blank
and Instruction 63 or 68 is used following this instruction to enter the variable
name.
Modbus Communication
This is the first coil or register to be acted upon when the instruction is
executed.
For general information on input locations, see Input Locations.
Summary of Contents for CR23X
Page 8: ...CR23X TABLE OF CONTENTS vi This is a blank page ...
Page 12: ...CR23X MICROLOGGER OVERVIEW OV 2 1 2 3 A 4 5 6 B 7 8 9 C 0 D FIGURE OV1 1 CR23X Micrologger ...
Page 34: ...CR23X MICROLOGGER OVERVIEW OV 24 This is a blank page ...
Page 50: ...SECTION 1 FUNCTIONAL MODES 1 16 This is a blank page ...
Page 72: ...SECTION 4 EXTERNAL STORAGE PERIPHERALS 4 8 This is a blank page ...
Page 88: ...SECTION 6 9 PIN SERIAL INPUT OUTPUT 6 10 This is a blank page ...
Page 110: ...SECTION 7 MEASUREMENT PROGRAMMING EXAMPLES 7 22 This is a blank page ...
Page 134: ...SECTION 8 PROCESSING AND PROGRAM CONTROL EXAMPLES 8 24 This is a blank page ...
Page 164: ...SECTION 9 INPUT OUTPUT INSTRUCTIONS 9 30 This is a blankpage ...
Page 188: ...SECTION 11 OUTPUT PROCESSING INSTRUCTIONS 11 8 This is a blankp age ...
Page 221: ...SECTION 13 CR23X MEASUREMENTS 13 21 FIGURE 13 5 1 Circuits Used with Instructions 4 9 ...
Page 229: ...14 3 1 2 3 A 4 5 6 B 7 8 9 C 0 D FIGURE 14 3 1 CR23X Battery Pack and Panel ...
Page 240: ...SECTION 14 INSTALLATION AND MAINTENANCE 14 14 This is a blank page ...
Page 244: ...APPENDIX A GLOSSARY A 4 This is a blank page ...
Page 268: ...APPENDIX B CONTROL PORT SERIAL I O INSTRUCTION 15 B 24 This is a blank page ...
Page 276: ...APPENDIX C BINARY TELECOMMUNICATIONS C 8 This is a blank page ...
Page 278: ...This is a blank page ...
Page 282: ...APPENDIX F DYNAGAGE SAP FLOW P67 F 4 This is a blank page ...
Page 299: ...APPENDIX I TD OPERATING SYSTEM ADDENDUM FOR CR510 CR10X AND CR23X MANUALS ...
Page 300: ...This is a blank page ...
Page 302: ...This is a blank page ...
Page 308: ...TABLE DATA ADDENDUM AD 6 This is a blank page ...
Page 324: ...TD ADDENDUM SECTION 1 FUNCTIONAL MODES AD 1 8 This is a blank page ...
Page 340: ...TD ADDENDUM SECTION 8 PROCESSING AND PROGRAM CONTROL EXAMPLES AD 8 10 This is a blank page ...
Page 342: ...This is a blank page ...
Page 373: ...This is a blank page ...