background image

symptom

possible Cause(s)

Corrective action

Tool runs slowly or will not 
operate .

1 .  Grit or gum in tool .

1 .   Flush the tool with air tool oil, gum 

solvent, or an equal mixture of SAE 10 
motor oil and kerosene . If air tool oil is not 
used, lubricate the tool after cleaning .

2 .  No oil in tool .

2 .   Lubricate the tool according to the 

lubrication instructions in this manual .

3 .  Low air pressure .

3a . Adjust the regulator on the tool to the 

maximum setting (If applicable) .

3b . Adjust the compressor regulator to tool 

maximum while the tool is running free .

4 .  Air hose leaks .

4 .   Tighten and seal hose fittings if leaks are 

found .

5 .  Pressure drops .

5a . Be sure the hose is the proper size . Long 

hoses or tools using large volumes of air 
may require a hose with an I .D . of 1/2 inch 
or larger depending on the total length of 
the hose .

5b . Do not use a multiple number of hoses 

connected together with quick connect 
fittings . This causes additional pressure 
drops and reduces the tool power . Directly 
connect the hoses together .

6 .  Worn rotor blade in motor .

6 .  Replace rotor blade .

7 .  Worn ball bearing in motor .

7 .  Remove and inspect bearing for rust, dirt 

and grit or worn race . Replace or clean and 
regrease bearing with bearing grease .

Moisture blowing out of 
tool .

1 .  Water in tank .

1 .   Drain tank . Oil tool and run until no water 

is evident . Oil tool again and run 1–2 
seconds .

2 .  Water in the air lines/hoses .

2a . Install a water separator/filter (PA2121) . 

NOTE: Separators only work properly when 
the air passing through the separator is 
cool .  Locate the separator/filter as far as 
possible from the compressor .

2b . Install an air dryer .
2c . Anytime water enters the tool, the tool 

should be oiled immediately .

Ratchet mechanism slips or 
will not loosen nut .

1 .  Ratchet mechanism is dirty .

1a . Clean mechanism with air tool oil .
1b . Replace worn mechanism .

Troubleshooting Chart

 

Stop using tool immediately if any of the following problems occur. Serious personal injury  

  could occur. Any repairs or replacements must be done by a Qualified Service Person or 

Authorized Service Center.

6

Operating Instructions

www.chpower.com

Summary of Contents for TL0501

Page 1: ...ich if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Caution indicates a potential...

Page 2: ...tentional starting Be sure the switch is off before connecting to the air supply Do not carry the tool with your finger on the switch or connect the tool to the air supply with the switch on d Remove...

Page 3: ...better and safer at the rate for which the tool is designed c Do not use the tool if the switch does not turn the tool on or off Any tool that cannot be controlled with the switch is dangerous and mus...

Page 4: ...all in one step After an air tool has been lubricated oil will discharge through the exhaust port during the first few seconds of operation Thus the ex haust port must be covered with a towel before...

Page 5: ...from heat oil and sharp edges Replace any hose that is damaged weak or worn User Maintenance Instructions Technical Service Please call our Tool Hotline at 1 800 543 6400 with any questions regarding...

Page 6: ...and reduces the tool power Directly connect the hoses together 6 Worn rotor blade in motor 6 Replace rotor blade 7 Worn ball bearing in motor 7 Remove and inspect bearing for rust dirt and grit or wor...

Page 7: ...7 TL0501 Notes www chpower com...

Page 8: ...he owner s manual s supplied with product Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety d...

Page 9: ...ion hasardeuse potentielle qui PEUT r sulter en blessures Avis indique de l information importante pour viter le dommage de l quipement REMARQUE L information qui exige une attention sp ciale Importan...

Page 10: ...i quelque chose se prend dans les pi ces mobiles c viter tout d marrage accidentel S assurer que l interrupteur est en position d arr t off avant de brancher l alimentation d air Ne pas transporter l...

Page 11: ...ne utilisation avec le mod le pr cis d outil augmente le risque de blessures pour les personnes i Choisir un syst me d activation de l outil appropri en tenant compte de l application de travail pr vu...

Page 12: ...ivr e l outil ne doit pas d passer 1 379 kPa L outil pourrait exploser ce qui pourrait mener la mort ou des blessures graves Conserver ces instructions Ne les jetez pas Mode d emploi graissage L utili...

Page 13: ...2 po REMARQUE Il n est pas recommand de monter un coupleur rapide entre l outil pneumatique et l amorce fl chie du tuyau Ne jamais transporter un outil en le tenant par le tuyau ni tirer sur celui ci...

Page 14: ...n diam tre int rieur de tuyau d au moins 1 2 po suivant la longeur totale du tuyau 5b Ne pas utiliser plusieurs tuyaux reli s ensemble au moyen de raccords rapides Cela provoque des chutes de pression...

Page 15: ...7 Fr TL0501 Notes...

Page 16: ...abusive par l acheteur la n gligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ces appar...

Page 17: ...reconocer los siguientes s mbolos sto le indica que hay una situaci n inmediata que LE OCASIONARIA la muerte o heridas de gravedad sto le indica que hay una situaci n que PODRIA ocasionarle la muerte...

Page 18: ...trabajo a Mantenga el rea de trabajo limpia y bien iluminada Los bancos desordenados y las reas oscuras aumentan el riesgo de choque el ctrico incendio y lesiones personales b No haga funcionar la he...

Page 19: ...s rotas y que no exista ning n otro problema que afecten el funcionamiento de la herramienta Si est da ada haga que le realicen un servicio a la herramienta antes de usarla Muchos accidentes son causa...

Page 20: ...ndo pero no limitado a ox geno y gases combustibles como fuente de energ a Use s lo aire comprimido filtrado lubricado y regulado El uso de un gas reactivo en vez de aire comprimido puede provocar que...

Page 21: ...i metro interno Para un rendimiento adecuado y una mayor conveniencia utilice una manguera de 9 5 mm 3 8 pulg de di metro interno Las mangueras de m s de 15 24 m 50 pies deben tener un di metro intern...

Page 22: ...utilizan grandes vol menes de aire pueden requerir una manguera con un di metro interno de 12 7 mm 1 2 pulg o mayor dependiendo del largo total de la manguera 5b No utilice varias mangueras conectada...

Page 23: ...7 Sp TL0501 Notas...

Page 24: ...rte del comprador o falta de operar el producto siguiendo las instrucciones del manual de instrucciones suministrado tambi n debe incluir la desconexi n o modificaci n de los instrumentos de seguridad...

Reviews: