background image

GEnERal

a .  

To reduce the risks of 
electric shock, fire, and 
injury to persons, read all 
the instructions before 
using the tool.

b .   Be thoroughly familiar with the 

controls and the proper use of the 
equipment . Follow all instructions . 
Contact your Campbell Hausfeld 
representative if you have any 
questions .

c .   Only persons well acquainted with 

these rules of safe operation should 
be allowed to use the unit .

 

Read and  

  understand tool 

labels and manual. Failure to follow 

warnings, dangers, and cautions 

could result in DEATH or SERIOUS 
INJURY.

WoRK aREa

a .  

Keep the work area clean and well 
lighted. 

Cluttered benches and dark 

areas increase the risks of electric 
shock, fire, and injury to persons . 

b .  

Do not operate the tool 
in explosive atmospheres, 
such as in the presence of 
flammable liquids, gases, 
or dust. 

The tool is able to create 

sparks resulting in the ignition of 
the dust or fumes . 

c .   

Keep bystanders, children, and 
visitors away while operating the 
tool.

 Distractions are able to result in 

the loss of control of the tool . 

pERsonal safETY

a .  

Stay alert. Watch what you are 
doing and use common sense 
when operating the tool. Do not 
use the tool while tired or under 
the influence of drugs, alcohol, 
or medication. 

A moment of 

inattention while operating the 
tool increases the risk of injury to 
persons . 

b .  

Dress properly. Do not wear loose 
clothing or jewelry. Contain long 
hair. Keep hair, clothing, and 
gloves away from moving parts. 

Loose clothes, jewelry, or long 
hair increases the risk of injury to 
persons as a result of being caught 
in moving parts . 

c .   

Avoid unintentional starting. 
Be sure the switch is off before 
connecting to the air supply. 

Do not 

carry the tool with your finger on 
the switch or connect the tool to the 
air supply with the switch on . 

d .  

Remove adjusting keys or wrenches 
before turning on the tool. 

A key or 

wrench attached to a rotating part 
of the tool may result in personal 
injury .

2

Operating Instructions

important safety instructions 

(Continued) 

e .  

Do not overreach. Keep proper 
footing and balance at all times. 

Proper footing and balance enables 
better control of the tool in 
unexpected situations . 

f .   

Use safety equipment. 

A dust mask, 

non-skid safety shoes and a hard 
hat must be used for the applicable 
conditions . 

g .  

Always wear eye 
protection.

 

h .  

Always wear hearing 
protection when using 
the tool. 

Prolonged 

exposure to high intensity 
noise is able to cause 
hearing loss . 

i .   

Do not attach the hose or tool to 
your body. 

Attach the hose to the 

structure to reduce the risk of loss of 
balance if the hose shifts .

 

Always remain in 

  a firmly balanced 

position when using or handling 

the tool.
 

Avoid long  

  extended periods 

of work with the tool. Stop using 

the tool if you feel pain in hands or 

arms.

j .   

Hold tool by insulated gripping 
surface when performing an 
operation where the tool may 
contact hidden wiring. 

Contacting a 

“live” wire will make exposed metal 
parts of the tool “live” and shock 
the operator .

Tool Components and specifications

 

www.chpower.com

Avg SCFM & psi  .  .  .  .  .  .  .  . 4 .8 @ 90 PSIG
 

(25% usage)

Continuous SCFM  .  .  .  .  .  . 19 .2 @ 90 PSIG
 

(100% usage)

Minimum Rated RPM  .  .  .  .  .  .  .  .  .  .  .  . 140

Max Torque  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .50 ft .lb .

Working Torque   .  .  .  .  .  .  .  .  . 10-45 ft .lb .

Gear Type  .  .  .  .  .  .  .  .  .  . 3 Idler Planetary

Bolt Capacity .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .3/8 inch

Air Inlet  .  .  .  .  .  .  .  . 1/4 inch NPT (Female)

Min . Hose Size   .  .  .  .  .  .  .  .  .  .  .  .  .  .3/8 inch

Drive  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3/8 inch sq .

Weight   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2 .5 lbs .

Forward/Reverse Dial

3/8 inch Anvil

Exhaust

Throttle

Air Inlet

Summary of Contents for TL0501

Page 1: ...ich if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Caution indicates a potential...

Page 2: ...tentional starting Be sure the switch is off before connecting to the air supply Do not carry the tool with your finger on the switch or connect the tool to the air supply with the switch on d Remove...

Page 3: ...better and safer at the rate for which the tool is designed c Do not use the tool if the switch does not turn the tool on or off Any tool that cannot be controlled with the switch is dangerous and mus...

Page 4: ...all in one step After an air tool has been lubricated oil will discharge through the exhaust port during the first few seconds of operation Thus the ex haust port must be covered with a towel before...

Page 5: ...from heat oil and sharp edges Replace any hose that is damaged weak or worn User Maintenance Instructions Technical Service Please call our Tool Hotline at 1 800 543 6400 with any questions regarding...

Page 6: ...and reduces the tool power Directly connect the hoses together 6 Worn rotor blade in motor 6 Replace rotor blade 7 Worn ball bearing in motor 7 Remove and inspect bearing for rust dirt and grit or wor...

Page 7: ...7 TL0501 Notes www chpower com...

Page 8: ...he owner s manual s supplied with product Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety d...

Page 9: ...ion hasardeuse potentielle qui PEUT r sulter en blessures Avis indique de l information importante pour viter le dommage de l quipement REMARQUE L information qui exige une attention sp ciale Importan...

Page 10: ...i quelque chose se prend dans les pi ces mobiles c viter tout d marrage accidentel S assurer que l interrupteur est en position d arr t off avant de brancher l alimentation d air Ne pas transporter l...

Page 11: ...ne utilisation avec le mod le pr cis d outil augmente le risque de blessures pour les personnes i Choisir un syst me d activation de l outil appropri en tenant compte de l application de travail pr vu...

Page 12: ...ivr e l outil ne doit pas d passer 1 379 kPa L outil pourrait exploser ce qui pourrait mener la mort ou des blessures graves Conserver ces instructions Ne les jetez pas Mode d emploi graissage L utili...

Page 13: ...2 po REMARQUE Il n est pas recommand de monter un coupleur rapide entre l outil pneumatique et l amorce fl chie du tuyau Ne jamais transporter un outil en le tenant par le tuyau ni tirer sur celui ci...

Page 14: ...n diam tre int rieur de tuyau d au moins 1 2 po suivant la longeur totale du tuyau 5b Ne pas utiliser plusieurs tuyaux reli s ensemble au moyen de raccords rapides Cela provoque des chutes de pression...

Page 15: ...7 Fr TL0501 Notes...

Page 16: ...abusive par l acheteur la n gligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ces appar...

Page 17: ...reconocer los siguientes s mbolos sto le indica que hay una situaci n inmediata que LE OCASIONARIA la muerte o heridas de gravedad sto le indica que hay una situaci n que PODRIA ocasionarle la muerte...

Page 18: ...trabajo a Mantenga el rea de trabajo limpia y bien iluminada Los bancos desordenados y las reas oscuras aumentan el riesgo de choque el ctrico incendio y lesiones personales b No haga funcionar la he...

Page 19: ...s rotas y que no exista ning n otro problema que afecten el funcionamiento de la herramienta Si est da ada haga que le realicen un servicio a la herramienta antes de usarla Muchos accidentes son causa...

Page 20: ...ndo pero no limitado a ox geno y gases combustibles como fuente de energ a Use s lo aire comprimido filtrado lubricado y regulado El uso de un gas reactivo en vez de aire comprimido puede provocar que...

Page 21: ...i metro interno Para un rendimiento adecuado y una mayor conveniencia utilice una manguera de 9 5 mm 3 8 pulg de di metro interno Las mangueras de m s de 15 24 m 50 pies deben tener un di metro intern...

Page 22: ...utilizan grandes vol menes de aire pueden requerir una manguera con un di metro interno de 12 7 mm 1 2 pulg o mayor dependiendo del largo total de la manguera 5b No utilice varias mangueras conectada...

Page 23: ...7 Sp TL0501 Notas...

Page 24: ...rte del comprador o falta de operar el producto siguiendo las instrucciones del manual de instrucciones suministrado tambi n debe incluir la desconexi n o modificaci n de los instrumentos de seguridad...

Reviews: