important safety instructions 

(Continued) 

 

Do not make any  

  modifications to 

the tool without first obtaining written 
approval from Campbell Hausfeld. Do 
not use the tool if any shields or guards 
are removed or altered. Do not use the 
tool as a hammer. Personal injury or 
tool damage may occur.

aiR soURCE

a .  

Never connect to an air source that 
is capable of exceeding 200 psi. 

Over pressurizing the tool is able 
to result in bursting, abnormal 
operation, breakage of the tool or 
serious injury to persons . Use only 
clean, dry, regulated compressed air 
at the rated pressure or within the 
rated pressure range as marked on 
the tool . Always verify prior to using 
the tool that the air source has been 
adjusted to the rated air pressure or 
within the rated air-pressure range . 

b .  

Never use oxygen, carbon dioxide, 
combustible gases or any bottled 
gas as an air source for the tool. 

Such gases are capable of explosion 
and serious injury to persons . 

 

Do not 

  use any 

type of reactive gases, 

including, but not 

limited to, oxygen and 

combustible gases, as a power 

source. Use filtered, lubricated, 

regulated compressed air only. 

Use of a reactive gas instead of 

compressed air may cause the tool 

to explode which will cause death 

or serious personal injury.
 

  Use only 

a pressure-regulated 

compressed air source 

to limit the air pressure 

opERaTinG insTRUCTions

lUbRiCaTion

Proper lubrication is the owner’s 
responsibility . Failure to lubricate the air 
tool properly will dramatically shorten 
the life of the tool and will void the 
warranty .

 

This air tool  

  requires 

lubrication before the initial 

use and before and after each 

additional use.

Air tools require lubrication throughout 
the life of the tool . Air tool oil is 
recommended because this oil cleans, 
lubricates and inhibits rust all in one 
step .

 

After an air tool  

  has been 

lubricated, oil will discharge 

through the exhaust port during 

the first few seconds of operation. 

Thus, the ex-haust port must 

be covered with a towel before 

applying air pressure. Failure to 

cover the exhaust port can result in 

serious injury.

1 .   Disconnect tool from air supply .
2 .   Turn tool upside down .
3 .   While pressing trigger, apply 5 - 10 

drops of oil in the air inlet .

4 .   Connect the air tool to the air supply 

and cover the exhaust port with a 
towel . Run the air tool for 7 to 10 

seconds . Oil will discharge from the 
exhaust port when air pressure is 
applied . 

RECoMMEnDED HooKUp

The illustration below shows the 
recommended hookup for the tool .
1 .   The air compressor 

must be able to 
maintain a minimum 
of 60 psi when the 
tool is being used . An inadequate air 
supply can cause a loss of power and 
inconsistent driving .

2 .   An oiler can be 

used to provide oil 
circulation through 
the tool . A filter can 
be used to remove 
liquid and solid impurities which can 
rust or “gum up” internal parts of 
the tool . 

3 .   Always use air supply hoses with 

a minimum working pressure 
rating equal to or greater than the 
pressure from the power source if a 
regulator fails, or 200 psi, whichever 
is greater . Use 1/4 inch air hose for 
runs up to 50 feet . Use 3/8 inch air 
hoses for 50 foot run or longer .

4 .   Use a pressure regulator on the 

compressor, with an operating 
pressure of 0 psi - 125 psi . A pressure 
regulator is required to control 
the operating pressure of the tool 
between 60 psi and 90 psi . 

200 psi or greater

3/8 inch I .D .

Recommended Hookup

Quick Plug

Quick 

Coupler

Air Hose

Quick Plug 

(Optional)

Quick 

Coupler 

(Optional)

Regulator

Lubricator

Filter

60 psi 

Min.
90 psi 

Max.

www.chpower.com

O

CO

2

90 psi

supplied to the tool. The regulated 

pressure must not exceed 90 psi. 

If the regulator fails, the pressure 

delivered to the tool must not 

exceed 200 psi. The tool could 

explode which will cause death or 

serious personal injury.

savE THEsE insTRUCTions 

Do noT DisCaRD

Summary of Contents for TL0501

Page 1: ...ich if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Caution indicates a potential...

Page 2: ...tentional starting Be sure the switch is off before connecting to the air supply Do not carry the tool with your finger on the switch or connect the tool to the air supply with the switch on d Remove...

Page 3: ...better and safer at the rate for which the tool is designed c Do not use the tool if the switch does not turn the tool on or off Any tool that cannot be controlled with the switch is dangerous and mus...

Page 4: ...all in one step After an air tool has been lubricated oil will discharge through the exhaust port during the first few seconds of operation Thus the ex haust port must be covered with a towel before...

Page 5: ...from heat oil and sharp edges Replace any hose that is damaged weak or worn User Maintenance Instructions Technical Service Please call our Tool Hotline at 1 800 543 6400 with any questions regarding...

Page 6: ...and reduces the tool power Directly connect the hoses together 6 Worn rotor blade in motor 6 Replace rotor blade 7 Worn ball bearing in motor 7 Remove and inspect bearing for rust dirt and grit or wor...

Page 7: ...7 TL0501 Notes www chpower com...

Page 8: ...he owner s manual s supplied with product Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety d...

Page 9: ...ion hasardeuse potentielle qui PEUT r sulter en blessures Avis indique de l information importante pour viter le dommage de l quipement REMARQUE L information qui exige une attention sp ciale Importan...

Page 10: ...i quelque chose se prend dans les pi ces mobiles c viter tout d marrage accidentel S assurer que l interrupteur est en position d arr t off avant de brancher l alimentation d air Ne pas transporter l...

Page 11: ...ne utilisation avec le mod le pr cis d outil augmente le risque de blessures pour les personnes i Choisir un syst me d activation de l outil appropri en tenant compte de l application de travail pr vu...

Page 12: ...ivr e l outil ne doit pas d passer 1 379 kPa L outil pourrait exploser ce qui pourrait mener la mort ou des blessures graves Conserver ces instructions Ne les jetez pas Mode d emploi graissage L utili...

Page 13: ...2 po REMARQUE Il n est pas recommand de monter un coupleur rapide entre l outil pneumatique et l amorce fl chie du tuyau Ne jamais transporter un outil en le tenant par le tuyau ni tirer sur celui ci...

Page 14: ...n diam tre int rieur de tuyau d au moins 1 2 po suivant la longeur totale du tuyau 5b Ne pas utiliser plusieurs tuyaux reli s ensemble au moyen de raccords rapides Cela provoque des chutes de pression...

Page 15: ...7 Fr TL0501 Notes...

Page 16: ...abusive par l acheteur la n gligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ces appar...

Page 17: ...reconocer los siguientes s mbolos sto le indica que hay una situaci n inmediata que LE OCASIONARIA la muerte o heridas de gravedad sto le indica que hay una situaci n que PODRIA ocasionarle la muerte...

Page 18: ...trabajo a Mantenga el rea de trabajo limpia y bien iluminada Los bancos desordenados y las reas oscuras aumentan el riesgo de choque el ctrico incendio y lesiones personales b No haga funcionar la he...

Page 19: ...s rotas y que no exista ning n otro problema que afecten el funcionamiento de la herramienta Si est da ada haga que le realicen un servicio a la herramienta antes de usarla Muchos accidentes son causa...

Page 20: ...ndo pero no limitado a ox geno y gases combustibles como fuente de energ a Use s lo aire comprimido filtrado lubricado y regulado El uso de un gas reactivo en vez de aire comprimido puede provocar que...

Page 21: ...i metro interno Para un rendimiento adecuado y una mayor conveniencia utilice una manguera de 9 5 mm 3 8 pulg de di metro interno Las mangueras de m s de 15 24 m 50 pies deben tener un di metro intern...

Page 22: ...utilizan grandes vol menes de aire pueden requerir una manguera con un di metro interno de 12 7 mm 1 2 pulg o mayor dependiendo del largo total de la manguera 5b No utilice varias mangueras conectada...

Page 23: ...7 Sp TL0501 Notas...

Page 24: ...rte del comprador o falta de operar el producto siguiendo las instrucciones del manual de instrucciones suministrado tambi n debe incluir la desconexi n o modificaci n de los instrumentos de seguridad...

Reviews: