background image

4

Portable Air Compressors

GROUNDING INSTRUCTIONS

This product must be grounded.  In 
the event of an electrical short circuit, 
grounding reduces the risk of electric 
shock by providing an escape wire 
for the electric current.  This product 
is equipped with a cord having a 
grounding wire with an appropriate 
grounding plug.  The plug must be 
plugged into an outlet that is properly 
installed and grounded in accordance 
with all local codes and ordinances.

 

improper installation 

  of the grounding 

plug is able to result in a risk of electric 
shock.  when repair or replacement of the 
cord or plug is required, do not connect 
the grounding wire to either flat blade 
terminal.  The wire with insulation having 
an outer surface that is green with or 
without yellow stripes is the grounding 
wire.
 

 Do not use adapter 

   with this product!

 

 Never connect  

   green (or green and 

yellow) wire to a live terminal.

Check with a qualified electrician 
or serviceman when the grounding 
instructions are not completely 
understood, or when in doubt as 
to whether the product is properly 
grounded.  Do not modify the plug 
provided; if it does not fit the outlet, 
have the proper outlet installed by a 
qualified technician. 
This product is for use on a nominal 
120V circuit and has a grounding plug 
similar to the plug illustrated in Figure 
4.  Only connect the product to an 
outlet having the same configuration 
as the plug.  Do not use an adapter 
with this product.

ExTENSION CORDS

 

To avoid loss of 

  power and 

overheating, it is better to use 
additional air hose instead of extension 
cords to reach work area. 

Use only a 3-wire extension cord that 
has a 3-blade grounding plug, and 
a 3-slot receptacle that accepts the 
plug on the product.  Make sure your 
extension cord is not damaged.  When 
using an extension cord, be sure to use 
one heavy enough to carry the current 
your product draws. An undersized 
cord results in a drop in line voltage 
and loss of power and overheating. 
[The table on page 3 shows the correct 
size to use depending on cord length 
and nameplate ampere rating. When 
in doubt, use the next heavier gauge.  
The smaller the gauge number, the 
heavier the cord.]

Operation

•  Pressure Switch

 - ON/OFF Switch 

(Figure 5) - In the ON position, the 
compressor shuts off automatically 
when tank pressure reaches the 
maximum preset pressure. In the 
OFF position, the compressor will 
not operate. This switch should be in 
the OFF position when connecting 
or disconnecting the power cord 
from the electrical outlet or when 
changing air tools.

• 

Regulator

 - The regulator controls 

the amount of air pressure released 
at the hose outlet.

• 

ASME Safety Valve

 - This valve 

automatically releases air if the 
tank pressure exceeds the preset 
maximum.

• 

Exhaust Tube

 - This tube carries 

compressed air from the pump to 
the check valve. This tube becomes 
very hot during use. To avoid the 
risk of severe burns, never touch 
the exhaust tube.

• 

Check Valve

  - A one-way valve 

that allows air to enter the tank, but 
prevents air in the tank from flowing 
back into the compressor pump.

• 

Handle

 - Designed to move the 

compressor.

• 

Drain Valve

 - This valve is located on 

the side of the tank. Use this valve to 
drain moisture from the tank daily to 
reduce the risk of corrosion.

 

Drain liquid from 

  tank daily.

Reduce tank pressure below 10 psi, then 
drain moisture from tank daily to avoid 
tank corrosion. Drain moisture from 
tank by opening the drain valve located 
underneath or on the side of the tank.

bEFORE FIRST START-UP 
bREAK-IN PROCEDURE 

(Complete this procedure before using 
compressor for the first time. Once 
completed, it is not necessary to repeat.)
1.  Turn regulator knob fully clockwise 

(to the right) to open air flow and 
open drain valve.

2.  Turn ON/OFF switch to OFF position.
3.  Plug in power cord.
4.  Turn ON/OFF switch to ON position 

and run compressor for 30 minutes.

www.chpower.com

MOISTURE IN COMPRESSED AIR

Moisture in compressed air will form into droplets as it comes from an air 
compressor pump. When humidity is high or when a compressor is in continuous use 
for an extended period of time, this moisture will collect in the tank. When using a 
paint spray or sandblast gun, this water will be carried from the tank through the 
hose, and out of the gun as droplets mixed with the spray material.

IMPORTANT: 

This condensation will cause water spots in a paint job, especially 

when spraying other than water based paints. If sandblasting, it will cause the sand 
to cake and clog the gun, rendering it ineffective. A filter in the air line, located as 
near to the gun as possible, will help eliminate this moisture.

Installation 

(Cont.)

 

TEST

RESET

Figure 4 - Grounding Method

Grounding 

Pin

Grounded 

Outlet

Figure 5 - ON/OFF Switch

Pressure 
Switch

Regulator Knob

Summary of Contents for HU3501

Page 1: ...eet minimal specifications for Grade D breathing as described in Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 and or Canadian Standards Associations CSA DISCLAIME...

Page 2: ...t and controls can cause electrical arcs that will ignite a flammable gas or vapor Never operate or repair the unit near a flammable gas or vapor Never store flammable liquids or gases in the vicinity...

Page 3: ...ventilated area so that compressor may be properly cooled 3 Compressor should be located where it can be directly plugged into an outlet but if this is not possible an extension cord may be used It sh...

Page 4: ...ally when tank pressure reaches the maximum preset pressure In the Off position the compressor will not operate This switch should be in the Off position when connecting or disconnecting the power cor...

Page 5: ...ached to regulator indicates air pressure going to hose and any tool attached to end of hose Gauge attached to pressure switch indicates air pressure in tank Maintenance Release all pressure and disco...

Page 6: ...becomes overheated If thermal overload protector shuts motor off frequently look for the following causes 1 Low voltage 2 Wrong gauge wire or length of extension cord 3 Clogged air filter 4 Lack of p...

Page 7: ...eter 2 Check gauge chart under Operation for proper gauge wire and cord length 3 Replace motor 4 Replace or repair 1 Check for proper fuse use time delay fuse Disconnect other electrical appliances fr...

Page 8: ...ited warranty The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product G Additional items not covered under this warranty 1 All Compressors a Any...

Page 9: ...r la respiration Grade D d crit dans le Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 et ou Canadian Standards Associations CSA D N GATION DES GARANTIES Si le comp...

Page 10: ...de ne pas toucher l xt rieur du moteur car il peut tre assez chaud pour causer des blessures 15 Prot ger le c ble lectrique contre les objets pointus 16 Nettoyer l quipement lectrique ou lectronique...

Page 11: ...38 C 100 F Un espace libre minimum de 45 7 centim tres 18 po entre le compresseur et un mur est exig pour viter le stoppage d air par des objets Ne pas situer la prise d air du compresseur pr s de la...

Page 12: ...ntes et v rifier que ces rallonges conviennent la fiche du produit V rifier que la rallonge n est pas endommag e En utilisant une rallonge s assurer d en utiliser une suffisamment lourde pour transpor...

Page 13: ...te automatiquement Si le compresseur reste en position ON marche et si l air sort compl tement du r servoir en utilisant un mandrin de pneu un outil etc alors le compresseur red marrera automatiqueme...

Page 14: ...it 14 Fr Compresseurs D Air Portatifs l extr mit du r servoir REMARQUE La coupe de vidange doit tre vid e r guli rement Ne retirez pas le bouchon de vidange le r servoir tant sous pression 4 Mettre le...

Page 15: ...ent pour le calibre de fil et la taille de cordon prolongateur corrects 3 Remplacer le moteur 4 Remplacer ou r parer 1 V rifier le type de fusible utiliser un fusible retardement D brancher les autres...

Page 16: ...est fournie avec le produit G Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Tous les Compresseurs a Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle...

Page 17: ...1 1966 de la Asociaci n de Aire Comprimido Igualmente deber cumplir los requisitos establecidos por el Articulo 29 CFR 1910 134 de la Organizaci n norteamericana OSHA y o la Canadian Standards Associa...

Page 18: ...s aislantes para evitar electrocutamiento Tenga cuidado al tocar la parte externa del motor encendido ste podr a estar lmuy caliente y ocasionarle heridas 15 Evite que el cord n el ctrico tenga contac...

Page 19: ...s ruedas puedan usarse para mover la unidad El juego de ensamble del mango incluye 1 mango 2 pernos 1 Inserte los extremos del mango en los soportes en forma de tubo en el tanque 2 Alinee los agujeros...

Page 20: ...cto est dise ado para funcionar en un circuito con una carga nominal de 120 v y tiene un enchufe de conexi n a tierra similar al enchufe ilustrado en la Figura 4 Conecte el producto nicamente a un tom...

Page 21: ...vula est ubicada en el lado del tanque sela para drenar la humedad del tanque diaria mente para evitar que el tanque se oxide Drene el tanque diariamente Reduzca la presi n del tanque a menos de 0 69...

Page 22: ...o 1 Chequee el compresor a ver si tiene alg n problema visible especialmente chequee el filtro de aire para cerciorarse de que est limpio 2 Hale el anillo de la v lvula de seguridad y deje que calce e...

Page 23: ...n de extensi n adecuado vea la secci n CORDONES DE EXTENSION p gina 15 2 Est conectado Chequee el fusible cortacircuito o protector de sobrecarga del motorfuse breaker or motor overload 3 Reemplace e...

Page 24: ...a otorgada por el fabricante del motor de gasolina que se suministra con el producto G Art culos adicionales no cubiertos bajo esta garant a 1 Todos los Compresores a Cualquier componente da ado dura...

Reviews: