background image

 

 

 

 

 

 

 

 

 

 

 
 
 
 

 
 
 

 
 
 
 
 
 

Summary of Contents for DK50 2V/50

Page 1: ......

Page 2: ......

Page 3: ...CONTENTS 3 INHALT 20 38 OBSAH 57 Ed 5...

Page 4: ...5 5 TECHNICAL DATA 6 6 PRODUCT DESCRIPTION 7 7 FUNCTION 7 INSTALLATION 10 8 USE 10 9 INSTALLATION 10 10 WIRING DIAGRAMS 12 11 PNEUMATIC DIAGRAM 15 12 FIRST OPERATION 16 OPERATION 16 13 SWITCHING THE C...

Page 5: ...Slovak version of the text prevails 2 2 General safety warnings The manufacturer developed and designed the equipment in such a way so that any risks were excluded if it is used according to intention...

Page 6: ...moisture Handling mark on package Temperature during storage and transport Handling mark on package Limited stacking Mark on package Recyclable material 4 STORAGE AND TRANSPORT The compressor is shipp...

Page 7: ...1 CONTINUAL S 1 CONTINUAL S 1 Mode of operation of compressor with dryer CONTINUAL S 1 CONTINUAL S 1 CONTINUAL S 1 CONTINUAL S 1 Dimensions of compressor of compressor with dryer w x l x h mm 595x475x...

Page 8: ...pressor is not suitable for the operation of breathing appliances or similar equipment 7 FUNCTION Compressor Fig 1 The compressor 1 draws in air through a filter 8 and compresses it through a check va...

Page 9: ...the ventilators shall be automatically switched off Make sure that nothing impedes the free flow of air under and around the compressor Never cover the hot air outlet on the top back side of the case...

Page 10: ...DK50 2V 50 DK50 4VR 50 03 2013 9 NP DK50 2V50 4VR50 5_03 2013 doc Fig 3 Compressor with dryer MONZUN M2 Fig 4 Box...

Page 11: ...eets all requirements for its use Refer to the technical data of the product for this purpose When a unit is to be built in classification and evaluation of compatibility must be done by the manufactu...

Page 12: ...ndproofing box by using the screwdriver Fig 6 Dental compressor in DK50 2V 50S M DK50 4VR 50S M Fig 4 Fig 5 After removing all packaging material place the product on the floor and remove stabilizatio...

Page 13: ...1 W V PE 3 N PE 400 230 V 50 Hz N U 1 3 2 4 5 6 A2 2 4 A1 1 3 6 5 03 04 3 M M1 150 C XC1 2 L N 1 L PE PE X1 PE 2 3 N N 1 PH 0000 h p SP1 40 C ST1 EV1 YV1 EV2 DK50 4VR 50 M2 30 11 2012 40 C ST1 FA1 KM1...

Page 14: ...50 M3 1 N PE 230V 50 60Hz 1 N PE 230V 50 60Hz 40 C ST1 1 3 2 4 FA1 N p SP1 A2 2 4 A1 1 3 KM1 N U EV1 M1 1 M B1 C PE PE X1 PE 2 3 N N 1 PH 0000 h TL ZP AST t x a Un IZ MON KT1 t a XC1 2 L N 1 L PE 16 1...

Page 15: ...t a W V PE N U 1 3 2 4 5 6 A2 2 4 A1 1 3 6 5 03 04 EV1 3 M M1 150 C XC1 2 L N 1 L PE 16 15 A1 T KT1 18 A2 T YV4 EV3 YV2 YV3 PE X1 PE 2 3 N N 1 PH 0000 h p SP1 N 3 N PE 400 230 V 50 Hz 3 N PE 400 230...

Page 16: ...17 10 11 PNEUMATIC DIAGRAM DK50 2V 50 M DK50 2V 50 1 Input filter for 4V 50 2x 2 Compressor motor 3 Compressor Fan 4 Solenoid valve 5 Safety valve 6 Check valve 7 Pressure switch 8 Air tank 9 Manomete...

Page 17: ...s lower limit level the compressor automatically switches on The compressor automatically switches off after reaching the pressure switch s upper limit level Compressor with dryer It is forbidden to a...

Page 18: ...ek 1 x day 1 x week check function operating staff operating staff operating staff Check safety valve 15 2 1 x year qualified technician Replacement of the input filter and prefilter 15 3 1 x 2 years...

Page 19: ...he safety valve releases air Let the safety valve blow out for only a few seconds Turn screw 4 to the right until it seats closing the valve The safety valve must never be used for depressurizing the...

Page 20: ...rator insert back and screw in I The container is definitely secured in the point of the symbol Fig 13 Water separator Order number Buoy Order number WS010BBFX 025200119 EF1 025200146 16 STORAGE If th...

Page 21: ...ed liquid in pressure vessel Check pneumatic distribution system seal loose joint Clean valve replace seals replace valve Drain condensed liquid Prolonged running of compressor Air leak in pneumatic d...

Page 22: ......

Page 23: ...PRODUKTBESCHREIBUNG 25 7 FUNKTIONSBESCHREIBUNG 25 INSTALLATION 28 8 NUTZUNGSBEDINGUNGEN 28 9 PRODUKTINSTALLATION 28 10 SCHALTPL NE 30 11 PNEUMATISCHES SCHEMA 33 12 ERSTE INBETRIEBNAHME 34 BEDIENUNG 34...

Page 24: ...r wurde das Ger t so entwickelt und gebaut dass jedwede Gefahren beim dessen bestimmungsgem en Gebrauch ausgeschlossen sind Der Hersteller h lt es f r seine Pflicht die nachstehenden Sicherheitsma nah...

Page 25: ...apelf higkeit Verpackungszeichen recyclebares Material 4 LAGER UND TRANSPORTBEDINGUNGEN Der Kompressor wird vom Hersteller in einer Transportverpackung geliefert Dadurch ist das Ger t gegen Transportb...

Page 26: ...1 dauerhaft S 1 dauerhaft S 1 Betriebsart des Kompressors mit Lufttrockner dauerhaft S 1 dauerhaft S 1 dauerhaft S 1 dauerhaft S 1 Abmessungen des Kompressors des Kompressors mit Trockner B x T x H m...

Page 27: ...DK50 4VR 50 M SKRINKA Kompressordruckluft ohne Filtrationseinrichtung ist nicht geeignet f r den Betrieb von Atemger ten oder hnlichen Ger ten 7 FUNKTIONSBESCHREIBUNG Kompressor Bild 1 Die Atmosph ren...

Page 28: ...sch ausgeschaltet Es ist verboten Hindernisse f r den K hlluftzufuhr in den Kasten am Umfang des Kastenunterteils und am Luftaustritt am oberen hinteren Kastenteil zu bilden Wird der Kompressor auf ei...

Page 29: ...DK50 2V 50 DK50 4VR 50 03 2013 27 NP DK50 2V50 4VR50 5_03 2013 doc Bild 3 Kompressor mit Lufttrockner MONZUN M2 Bild 4 Kasten...

Page 30: ...s bei der Aufstellung des Ger tes eine Klassifizierung und Bewertung der bereinstimmung des Mediums Luft durchf hren Eine Nutzung des Ger tes ber den vorgesehenen Rahmen hinaus ist nicht zul ssig Der...

Page 31: ...M DK50 4VR 50S M Bild 4 Bild 5 Das Produkt nach Auspackung mit der Basis auf den Boden stellen Verpackungsteile entfernen und Fixierteile Y Detail A abnehmen Den Kompressor im Kasten gleich wie im ob...

Page 32: ...2 4 5 6 A2 2 4 A1 1 3 6 5 03 04 3 M M1 150 C XC1 2 L N 1 L PE PE X1 PE 2 3 N N 1 PH 0000 h p SP1 40 C ST1 EV1 YV1 EV2 DK50 4VR 50 M2 30 11 2012 40 C ST1 FA1 KM1 TL ZP AST t x a Un IZ MON KT1 t a W V...

Page 33: ...FA1 N p SP1 A2 2 4 A1 1 3 KM1 N U EV1 M1 1 M B1 C PE PE X1 PE 2 3 N N 1 PH 0000 h TL ZP AST t x a Un IZ MON KT1 t a XC1 2 L N 1 L PE 16 15 A1 T KT1 18 A2 T YV4 EV3 YV2 YV3 HL1 Q 40 C ST2 EV4 Trockner...

Page 34: ...M M1 150 C XC1 2 L N 1 L PE 16 15 A1 T KT1 18 A2 T YV4 EV3 YV2 YV3 PE X1 PE 2 3 N N 1 PH 0000 h p SP1 N 3 N PE 400 230 V 50 Hz 3 N PE 400 230 V 50 Hz 3 N PE 400 230 V 50 Hz 3 N PE 400 230 V 50 Hz NET...

Page 35: ...SCHEMA DK50 2V 50 M DK50 2V 50 1 Eingangsfilter bei 4V 50 2x 2 Kompressoraggregat 3 Kompressorventilator 4 Magnetventil 5 Sicherheitsventil 6 R ckschlagventil 7 Druckschalter 8 Druckluftspeicher 9 Dru...

Page 36: ...t sich der K hlventilator wieder aus Automatischer Betrieb des Produktes Wenn der Druck im Druckbeh lter auf den Einschaltdruck sinkt wird der Kompressor automatisch eingeschaltet Der Kompressor schal...

Page 37: ...essoren ohne Lufttrockner bei hoher Luftfeuchtigkeit Kompressoren mit Lufttrockner 15 1 1 x pro Woche 1 x t glich 1 x pro Woche Funktionstest Nutzer Nutzer Nutzer Sicherheitsventilkontrolle 15 2 1 x p...

Page 38: ...5 2 Kontrolle des Sicherheitsventils Bild 8 Bei der ersten Inbetriebnahme des Kompressors ist es notwendig die ordnungsgem e Funktion des Sicherheitsventils zu kontrollieren Die Schraube 4 des Sicherh...

Page 39: ...etzen und nach rechts eindrehen 15 5 Schwimmeraustausch im Wasserabscheider Bild 13 Bei regelm igem Trocknerbetrieb ist der Schwimmer im Wasserabscheider zu wechseln A System drucklos machen B Das Abs...

Page 40: ...inen negativen Einfluss auf die Umwelt 18 INFORMATIONEN BER REPARATURBETRIEBE Garantieleistungen und Reparaturen nach Ablauf der Garantie werden durch den Hersteller durch vom Hersteller benannte Firm...

Page 41: ...r durch neue filter ersetzen Ausgangsfilter im Trockner wechseln bzw auch die F llung ersetzen wenn sie zerf llt oder stark verunreinigt ist Ventil reparieren oder wechseln Kompressor ist laut Klopfen...

Page 42: ...DK50 2V 50 DK50 4VR 50 NP DK50 2V50 4VR50 5_03 2013 doc 40 03 2013 41 1 CE 41 2 41 3 42 4 43 5 43 6 44 7 45 47 8 47 9 47 10 A 50 11 53 12 54 54 13 54 55 14 55 15 55 16 58 17 58 18 58 19 58 79...

Page 43: ...DK50 2V 50 DK50 4VR 50 03 2013 41 NP DK50 2V50 4VR50 5_03 2013 doc 1 CE CE 93 42 EEC 2 2 1 2 2...

Page 44: ...DK50 2V 50 DK50 4VR 50 NP DK50 2V50 4VR50 5_03 2013 doc 42 03 2013 2 3 3 CE...

Page 45: ...4 5 4 9 7 6 4 6 5 3 A 7 6 4 7 5 2 7 8 4 7 5 6 1 1 1 5 2 2 1 1 1 5 2 2 50 50 50 50 6 0 8 0 6 0 8 0 6 0 8 0 6 0 8 0 12 0 12 0 12 0 12 0 LpfA 71 75 56 59 S 1 S 1 S 1 S 1 S 1 S 1 S 1 S 1 x x 595x475x770 5...

Page 46: ...5_03 2013 doc 44 03 2013 25 C 55 C 24 70 C 10 90 5 C 40 C 70 6 6 1 DK50 2V 50 DK50 2V 50 M M3 DK50 2V 50S DK50 2V 50S M M3 DK50 4VR 50 DK50 4VR 50 M M2 DK50 4VR 50S DK50 4VR 50S M M2 DK50 2V 50 DK50 2...

Page 47: ...DK50 2V 50 DK50 4VR 50 03 2013 45 NP DK50 2V50 4VR50 5_03 2013 doc 7 1 A a 1 8 3 2 4 21 5 7 M2 M3 2 3 1 8 19 12 9 18 16 3 2 10 Skrinka kompresora 4 13 40 C 22 32 C...

Page 48: ...0 2V 50 DK50 4VR 50 NP DK50 2V50 4VR50 5_03 2013 doc 46 03 2013 1 2 MONZUN M3 3 MONZUN M2 1 A a 2 3 4 5 6 7 8 9 o 10 c 11 12 13 14 15 O 16 17 18 19 20 a 21 22 a 23 24 25 26 a 27 a 28 29 C 30 o 31 o 32...

Page 49: ...DK50 2V 50 DK50 4VR 50 03 2013 47 NP DK50 2V50 4VR50 5_03 2013 doc 4 8 5 C 40 C 70 5 9...

Page 50: ...0 NP DK50 2V50 4VR50 5_03 2013 doc 48 03 2013 9 1 5 DK50 2V 50 DK50 2V 50 M DK50 4VR 50 DK50 4VR 50 M 5 X Y A DK50 2V 50S DK50 4VR 50S 4 5 Y A 32 2 29 30 31 27 25 29 26 6 DK50 2V 50S M DK50 4VR 50S M...

Page 51: ...DK50 2V 50 DK50 4VR 50 03 2013 49 NP DK50 2V50 4VR50 5_03 2013 doc 7 1 9 2 7 1 9 3 8 16 A 6 1 2 8...

Page 52: ...e 10 bar EV2 EV5 3 N PE 400 230 V 50 Hz TN S TN C S 1 KT1 90s 10bar 3 N PE 400 230 V 50 Hz TN S TN C S 1 10bar SP EV1 EV2 ST1 EV3 M1 FA1 YV1 YV2 YV4 OUT KM1 YV3 X1 KT1 PH1 XC1 Q HL1 ST2 EV4 EV5 CB1 DK...

Page 53: ...1 N PE 230V 50 60Hz ELEKTRICK PREDMET TR I TYP B 40 C ST1 1 3 2 4 FA1 N p SP1 A2 2 4 A1 1 3 KM1 N U EV1 M1 1 M B1 C PE PE X1 PE 2 3 N N 1 PH 0000 h len pre 10 bar asov rel KT1 90 sek TL ZP AST t x a U...

Page 54: ...M1 150 C XC1 2 L N 1 L PE 16 15 A1 T KT1 18 A2 T YV4 EV3 SU I YV2 YV3 PE X1 PE 2 3 N N 1 PH 0000 h p SP1 N len pre 10 bar 40 C ST1 FA1 KM1 asov rel KT1 90 sek TL ZP AST t x a Un IZ MON KT1 t a W V PE...

Page 55: ...2V 50 DK50 4VR 50 03 2013 53 NP DK50 2V50 4VR50 5_03 2013 doc 1 2 6 5 7 8 9 3 4 1 2 3 7 8 9 11 10 12 5 13 14 15 6 6 16 16 17 10 11 DK50 2V 50 M DK50 2V 50 1 4V 50 2x 2 3 4 5 6 7 8 9 10 11 12 13 14 15...

Page 56: ...DK50 2V 50 DK50 4VR 50 NP DK50 2V50 4VR50 5_03 2013 doc 54 03 2013 12 9 2 3 I e 24 4 I 40 C 32 C 13 9 3 I 24 4 9 3 5 2 1 4...

Page 57: ...4VR50 5_03 2013 doc 10 2 a M2 M3 O O DK50 2V 50 M3 0 6 mm 6 8 bar 140 l min 30 l min 6bar DK50 4VR 50 M2 0 85 mm 5 8 bar 280 l min 50 l min 5bar 14 e o e e 24 EN 62353 EN 62353 G 15 1 1 1 1 15 2 1 15...

Page 58: ...DK50 2V 50 DK50 4VR 50 NP DK50 2V50 4VR50 5_03 2013 doc 56 03 2013 11 14 15 1 10 1 1 1 15 2 9 4 1 4 15 3 11 1 3 2 3 1 10...

Page 59: ...DK50 2V 50 DK50 4VR 50 03 2013 57 NP DK50 2V50 4VR50 5_03 2013 doc 12 15 4 12 4 1 2 3 15 5 13 A B C D E F G H A 13 WS010BBFX 025200119 EF1 025200146 A B C D E F G H I...

Page 60: ...DK50 2V 50 DK50 4VR 50 NP DK50 2V50 4VR50 5_03 2013 doc 58 03 2013 16 10 1 10 3 2 9 17 1 10 18 19 0 6 0 7 1...

Page 61: ...DK50 2V 50 DK50 4VR 50 03 2013 59 NP DK50 2V50 4VR50 5_03 2013 doc O...

Page 62: ...63 6 POPIS V ROBKU 64 7 POPIS FUNKCIE 64 IN TAL CIA 67 8 PODMIENKY POU ITIA 67 9 IN TALOVANIE V ROBKU 67 10 SCH MY ZAPOJENIA 69 11 PNEUMATICK SCH MY 72 12 PRV UVEDENIE DO PREV DZKY 73 OBSLUHA 73 13 Z...

Page 63: ...n ak ko vek nebezpe ia pri spr vnom pou van pod a ur enia V robca pova uje za svoju povinnos pop sa nasleduj ce bezpe nostn opatrenia aby sa mohli vyl i zbytkov po kodenia Pri prev dzke pr stroja treb...

Page 64: ...lota skladovania a prepravy Manipula n zna ka na obale Obmedzen stohovanie Zna ka na obale Recyklovate n materi l 4 SKLADOVACIE A PREPRAVN PODMIENKY Kompresor sa zo z vodu zasiela v prepravnom obale T...

Page 65: ...ora trval S 1 trval S 1 trval S 1 trval S 1 Re im prev dzky kompresora so su i om trval S 1 trval S 1 trval S 1 trval S 1 Rozmery kompresora kompresora so su i om x h x v mm 595x475x770 595x585x770 59...

Page 66: ...0 DK50 2V 50 M DK50 4VR 50 M DK50 4VR 50 M SKRINKA Stla en vzduch kompresora nie je vhodn bez pr davn ho filtra n ho zariadenia na prev dzkovanie d chac ch pr strojov alebo podobn ch zariaden 7 POPIS...

Page 67: ...uchu do skrinky po obvode spodnej asti skrinky a na v stupe tepl ho vzduchu v hornej zadnej asti skrinky V pr pade ustavenia kompresora na m kk podlahu napr koberec je nutn vytvori medzeru medzi z kla...

Page 68: ...DK50 2V 50 DK50 4VR 50 NP DK50 2V50 4VR50 5_03 2013 doc 66 03 2013 Obr 3 Kompresor so su i om vzduchu MONZUN M2 Obr 4 Skrinka...

Page 69: ...dispoz cii vyhovovalo po iadavk m dan ho elu pou itia Re pektujte za t mto elom technick daje v robku Klasifik ciu a hodnotenie zhody m pri zabudovan vykon va v robca dod vate kone n ho v robku In pou...

Page 70: ...4 Obr 5 V robok po vybalen z obalu postavi z klad ou na podlahu miestnosti uvo ni ho od obalov ch materi lov a odstr ni fixa n diely Y detail A Kompresor umiestni do skrinky rovnako ako v predch dzaj...

Page 71: ...PE 3 N PE 400 230 V 50 Hz ELEKTRICK SIE TN S TN C S ELEKTRICK PREDMET TR I TYP B N U 1 3 2 4 5 6 A2 2 4 A1 1 3 6 5 03 04 3 M M1 150 C XC1 2 L N 1 L PE PE X1 PE 2 3 N N 1 PH 0000 h p SP1 40 C ST1 EV1...

Page 72: ...0000 h len pre 10 bar asov rel KT1 90 sek TL ZP AST t x a Un IZ MON KT1 t a XC1 2 L N 1 L PE 16 15 A1 T KT1 18 A2 T YV4 EV3 SU I YV2 YV3 DK50 2VS 50 M3 1 N PE 230V 50 60Hz ELEKTRICK PREDMET TR I TYP B...

Page 73: ...len pre 10 bar 40 C ST1 FA1 KM1 asov rel KT1 90 sek TL ZP AST t x a Un IZ MON KT1 t a W V PE N U 1 3 2 4 5 6 A2 2 4 A1 1 3 6 5 03 04 EV1 3 M M1 150 C XC1 2 L N 1 L PE 16 15 A1 T KT1 18 A2 T YV4 EV3 SU...

Page 74: ...PNEUMATICK SCH MY DK50 2V 50 M DK50 2V 50 1 Vstupn filter pri 4V 50 2x 2 Kompresor 3 Ventil tor 4 Solenoidov ventil 5 Poistn ventil 6 Sp tn ventil 7 Tlakov sp na 8 Vzdu n k 9 Manometer 10 Solenoidov...

Page 75: ...k spustenie Ke tlak v tlakovej n dr i poklesne na zap nac tlak kompresor sa automaticky zapne Kompresor sa automaticky vypne ke dosiahne tlak vo vzdu n ku vyp nac tlak Kompresor so su i om Je zak zan...

Page 76: ...a t de 1 x za de 1 x za t de kontrolova funkciu u vate u vate u vate Skontrolova poistn ventil 15 2 1 x ro ne kvalifikovan odborn k V mena vstupn ho filtra a predfiltra 15 3 1 x za 2 roky alebo po 500...

Page 77: ...ebn otvori skrinku pred nasledovn mi kontrolami 15 2 Kontrola poistn ho ventilu Obr 9 Pri prvom uveden kompresora do prev dzky treba skontrolova spr vnu funkciu poistn ho ventilu Skrutku 4 poistn ho v...

Page 78: ...prava 15 5 V mena plav ku v odlu ova i vody Obr 13 Pri pravidelnej prev dzke su i a je potrebn vymeni plav k v odlu ova i vody B Uvolni tlak C Demontova n dobku odlu ova a D Vytiahnu separ tor kondenz...

Page 79: ...odpadu zada pecializovanej organiz cii asti v robku po skon en jeho ivotnosti nemaj negat vny vplyv na ivotn prostredie 18 INFORM CIE O OPRAV RENSKEJ SLU BE Z ru n a mimoz ru n opravy zabezpe uje v r...

Page 80: ...spoj utesni Opotreben piestne kr ky vymeni Zne isten filtre nahradi nov mi Vymeni v stupn filter v komore pr p aj n pl ak sa rozpad alebo je ve mi pra n Opravi alebo vymeni ventil Kompresor je hlu n...

Page 81: ...nungs und Instandhaltungsanleit ung Garantieschein N vod na in tal ciu obsluhu a dr bu NP DK50 2V 50 4VR 1x Fuse Sicherung Poistka T0 8A 35 038100006 2x Wall stopper Distanzst cke Doraz stenov 0230002...

Page 82: ...l stopper Distanzst cke Doraz stenov 023000276 2x Transport mechanism Verschiebemechanis mus o Od ah 603021540 1x DK50 4VR 50S M 1x Installation Operation and Maintenance Manual Installations Bedienun...

Page 83: ...otwendig diese Ausstattung gesondert zu bestellen Doplnkov vybavenie nie je predmetom z kladnej dod vky treba ho objedna osobitne Plug for mains connection Steckdose f r quipotenziellen Potentialausgl...

Page 84: ......

Reviews: