  Gauge of Cord 

 

16 

14 

10

 

 

     Extension cords for 120V/10 Amp Unit

  Length of Cord (ft) 

 

25 

50 

100

HU3501

3

Assembly

ASSEMbLY TOOLS REqUIRED

Tools (not provided) for assembly:

-  2 14mm wrench or socket wrench 

-  2 17mm wrench or socket wrench

FOOT ASSEMbLY (FIGURE 1)

Foot assembly kit includes:

-  1 rubber foot

-  1 bolt

-  2 washers

-  1 nut

WHEEL ASSEMbLY (FIGURE 2)

Wheel assembly kit includes:
-  2 wheels*
-  2 axle bolts*
-  2 lock washers*
-  2 nuts*
The items marked with an asterisk (*) 
were shipped loose with the unit.

1.  Wheel has an offset hub. With offset 

hub facing axle iron, assemble axle bolt 
through holes in wheel and axle iron.

2.  Place lock washer on axle bolt. Then 

tighten nut securely to threaded 
part of axle bolt.

3.  Repeat procedure with other side.

HANDLE ASSEMbLY (FIGURE 3)

 

Never use the 

  handle to lift the 

unit completely off the ground. only 
use the handle to lift one end so the 
wheels may be used to move the unit.

Handle assembly kit includes:
-  1 handle
-  2 bolts
1.  Insert ends of handle into tube 

shaped brackets on tank.

2.  Align screw holes.
3.  Thread screw into hole until tight.

Installation

LOCATION

It is extremely important to install the 
compressor in a clean, well ventilated area 
where the surrounding air temperature 
will not be more than 100°F.
A minimum clearance of 18 inches between 
the compressor and a wall is required 
because objects could obstruct air flow.

 

Do not locate the 

  compressor air inlet 

near steam, paint spray, sandblast areas 
or any other source of contamination. This 
debris will damage the motor

Household use only. Store indoors.

ELECTRICAL INSTALLATION

1.  Check and tighten all bolts, fittings, 

etc., before operating compressor.

2.  Operate compressor in a ventilated 

area so that compressor may be 
properly cooled.

3.  Compressor should be located where 

it can be directly plugged into an 
outlet, but if this is not possible, an 
extension cord may be used. It should 
be selected using the extension cord 
chart on page 3 as a guide.

4.  To avoid loss of power and 

overheating, it is better to use 
additional air hose instead of 
extension cords to reach work area.

WIRING

1.  Local electrical wiring codes 

differ from area to area. Source 
wiring, plug and protector must 
be rated for at least the amperage 
and voltage indicated on motor 
nameplate, and meet all electrical 
codes for this minimum .

2.  Use a slow blow fuse type T or a 

circuit breaker.

 

 overheating, short  

   circuiting and fire 

damage will result from inadequate 
wiring, etc.
 

All wiring and 

  electrical 

connections should be performed by a 
qualified electrician. installation must 
be in accordance with local codes and 
national electrical codes.

NOTE: 

120 volt, compressor can be 

operated on a 120 volt, 15 amp circuit 
under the following conditions:

a. No other electrical appliances or 

lights are connected to the same 
branch circuit.

b. Voltage supply is normal.
c. Extension cords are of the 

minimum gauge specified in this 
instruction manual.

d. Circuit is equipped with a 15 amp 

circuit breaker or a 15 amp slow 
blow fuse type T.

3.  If above conditions cannot be met 

or if nuisance tripping of current 
protection device occurs, it may be 
necessary to operate compressor 
from a 120 volt, 20 amp circuit.

  Power cord 

White 

Line 

No

  Motor cord 

White 

Load 

No

  Power cord 

Black 

Line 

Yes

  Motor cord 

Black 

Load 

Yes

✽ 

Wire and Terminal Guide

  Wire 

Color 

Terminal 

Hot

(

When the unit is not in operation

www.chpower.com

 

Wheel

Axle Bolt

Lock 
Washer

Nut

Figure 2 - Wheel assembly

Bolt

Handle

Tank

Figure 3 - Handle Assembly

Rubber Foot

Washer

Bolt

Washer

Nut

Figure 1 - Rubber foot installation

Summary of Contents for HU3501

Page 1: ...eet minimal specifications for Grade D breathing as described in Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 and or Canadian Standards Associations CSA DISCLAIME...

Page 2: ...t and controls can cause electrical arcs that will ignite a flammable gas or vapor Never operate or repair the unit near a flammable gas or vapor Never store flammable liquids or gases in the vicinity...

Page 3: ...ventilated area so that compressor may be properly cooled 3 Compressor should be located where it can be directly plugged into an outlet but if this is not possible an extension cord may be used It sh...

Page 4: ...ally when tank pressure reaches the maximum preset pressure In the Off position the compressor will not operate This switch should be in the Off position when connecting or disconnecting the power cor...

Page 5: ...ached to regulator indicates air pressure going to hose and any tool attached to end of hose Gauge attached to pressure switch indicates air pressure in tank Maintenance Release all pressure and disco...

Page 6: ...becomes overheated If thermal overload protector shuts motor off frequently look for the following causes 1 Low voltage 2 Wrong gauge wire or length of extension cord 3 Clogged air filter 4 Lack of p...

Page 7: ...eter 2 Check gauge chart under Operation for proper gauge wire and cord length 3 Replace motor 4 Replace or repair 1 Check for proper fuse use time delay fuse Disconnect other electrical appliances fr...

Page 8: ...ited warranty The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product G Additional items not covered under this warranty 1 All Compressors a Any...

Page 9: ...r la respiration Grade D d crit dans le Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 et ou Canadian Standards Associations CSA D N GATION DES GARANTIES Si le comp...

Page 10: ...de ne pas toucher l xt rieur du moteur car il peut tre assez chaud pour causer des blessures 15 Prot ger le c ble lectrique contre les objets pointus 16 Nettoyer l quipement lectrique ou lectronique...

Page 11: ...38 C 100 F Un espace libre minimum de 45 7 centim tres 18 po entre le compresseur et un mur est exig pour viter le stoppage d air par des objets Ne pas situer la prise d air du compresseur pr s de la...

Page 12: ...ntes et v rifier que ces rallonges conviennent la fiche du produit V rifier que la rallonge n est pas endommag e En utilisant une rallonge s assurer d en utiliser une suffisamment lourde pour transpor...

Page 13: ...te automatiquement Si le compresseur reste en position ON marche et si l air sort compl tement du r servoir en utilisant un mandrin de pneu un outil etc alors le compresseur red marrera automatiqueme...

Page 14: ...it 14 Fr Compresseurs D Air Portatifs l extr mit du r servoir REMARQUE La coupe de vidange doit tre vid e r guli rement Ne retirez pas le bouchon de vidange le r servoir tant sous pression 4 Mettre le...

Page 15: ...ent pour le calibre de fil et la taille de cordon prolongateur corrects 3 Remplacer le moteur 4 Remplacer ou r parer 1 V rifier le type de fusible utiliser un fusible retardement D brancher les autres...

Page 16: ...est fournie avec le produit G Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Tous les Compresseurs a Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle...

Page 17: ...1 1966 de la Asociaci n de Aire Comprimido Igualmente deber cumplir los requisitos establecidos por el Articulo 29 CFR 1910 134 de la Organizaci n norteamericana OSHA y o la Canadian Standards Associa...

Page 18: ...s aislantes para evitar electrocutamiento Tenga cuidado al tocar la parte externa del motor encendido ste podr a estar lmuy caliente y ocasionarle heridas 15 Evite que el cord n el ctrico tenga contac...

Page 19: ...s ruedas puedan usarse para mover la unidad El juego de ensamble del mango incluye 1 mango 2 pernos 1 Inserte los extremos del mango en los soportes en forma de tubo en el tanque 2 Alinee los agujeros...

Page 20: ...cto est dise ado para funcionar en un circuito con una carga nominal de 120 v y tiene un enchufe de conexi n a tierra similar al enchufe ilustrado en la Figura 4 Conecte el producto nicamente a un tom...

Page 21: ...vula est ubicada en el lado del tanque sela para drenar la humedad del tanque diaria mente para evitar que el tanque se oxide Drene el tanque diariamente Reduzca la presi n del tanque a menos de 0 69...

Page 22: ...o 1 Chequee el compresor a ver si tiene alg n problema visible especialmente chequee el filtro de aire para cerciorarse de que est limpio 2 Hale el anillo de la v lvula de seguridad y deje que calce e...

Page 23: ...n de extensi n adecuado vea la secci n CORDONES DE EXTENSION p gina 15 2 Est conectado Chequee el fusible cortacircuito o protector de sobrecarga del motorfuse breaker or motor overload 3 Reemplace e...

Page 24: ...a otorgada por el fabricante del motor de gasolina que se suministra con el producto G Art culos adicionales no cubiertos bajo esta garant a 1 Todos los Compresores a Cualquier componente da ado dura...

Reviews: