- Whenever  the  use  of  the  device  does  not  conform

to the instructions and information described in this

manual.

- In  case  of  changes  or  variations  made  without

authorization of the manufacturer.

- In  case  of  technical  interventions  executed  by  a

non-authorized personnel.

- In case of failing to carry out adequate maintenance.

1.5 Technical assistance

Any  further  information  about  the  documentation,

technical assistance and spare parts, shall be reque-

sted from: Calpeda S.p.A. (paragraph 1.2).

2 TECHNICAL DESCRIPTION

Single-impeller  submersible  pumps  in  chrome-nickel

stainless steel, with vertical delivery port.

GXR: with open impeller.

GXV: with free-flow (vortex) impeller.

Motor cooled by the pumped water passing between

the motor jacket and the external jacket.

Double shaft seal with oil chamber.

2.1 Intended use

Standard construction

- GXR with open impeller.

For  clean  or  slightly  dirty  water,  with  solids  in

suspension  up  to  10  mm  grain  size  (12 mm  for

GXR 12)

.

- GXV with free-flow (vortex) impeller

For  clean  or  slightly  dirty  water,  with  solids  in

suspension up to 25 mm grain size.

- Maximum liquid temperature: 50 °C.

- Maximum liquid density: 1100 kg/m

3

.

- Maximum immersion depth: 5 m (with cable of sui-

table length).

For outdoor use the power supply cable must have

a length of not less  than 10 m.

2.2 Improper use

The device is designed and built only for the purpose

described in paragraph 2.1.

Do  not  use  in  garden  ponds,  tanks  or

swimming  pools  when  people  are  in  the

water.
The Pump cannot be used in explosive or

flammable environments.

Improper use of the device is forbidden, as is

use  under  conditions  other  than  those

indicated in these instructions.

Improper  use  of  the  product  reduces  the  safety  and

the  efficiency  of  the  device,  Calpeda  shall  not  be

responsible  for  failure  or  accident  due  to  improper

use.

2.3 Marking

The following picture is a copy of the name-plate that

is on the external case of the pump.

3 TECHNICAL FEATURES

3.1 Technical data

Dimensions and weight (paragraph 12.1).

Nominal speed 2900/3450 rpm

Protection IP X8

Supply voltage / Frequency

230V 1~  50 Hz

230V, 400V 3~ 50 Hz

220V 1~  60 Hz

220V, 380V 3~ 60 Hz

Sound  pressure  at  minimum  immersion  depth:  <  70

dB (A).

Noise  disappears  or  decreases when  the  pump  is

submersed.

Maximum starts/hour: 30 at regular intervals.

Maximum  permissible  working  pressure  up  to  60  m

(6 bar).

4 SAFETY

4.1 General provisions

Before  using  the  product  it  is  necessary  to

know  all the safety indications.

Carefully  read  all  operating  instructions  and

the indications defined for the different steps:

from transportation to disposal.

The  specialized  technicians  must  carefully

comply with all applicable standards and laws,

including  local  regulations  of  the  country

where the pump is sold.

The  device  has  been  built  in  conformity  with

the  current  safety  laws.  The  improper  use

could damage people, animals and objects.

The  manufacturer  declines  any  liability  in  the

event of damage due to improper use or use

under conditions other than those indicated on

the name-plate and in these instructions.

Follow  the  routine  maintenance  schedules

and the promptly replace damaged parts, this

will  allows  the  device  to  work  in  the  best

conditions.

Use  only  original  spare  parts  provided  from

Calpeda  S.p.A  or  from  an  authorized

distributor.

Don't remove or change the labels placed on

the device. 

Do  not  start  the  device  in  case  of  defects  or

damaged parts.

Maintenance  operations,  requiring  full  or

partial  disassembly  of  the  device,  must  be

done only after disconnection from the supply.

4.2 Safety devices

The  device  has  an  external  case  that  prevents  any

contact with internal parts.

4.3 Residual risks

The  appliance,  designed  for  use,  when  used  in-line

with  the  design  and  safety  rules,  doesn't  have  resi-

dual risks.

4.4 Information and Safety signals

For this kind of product there will not be any signals

on the product.

4.5 Individual protection devices

During  installation,  starting  and  maintenance  it  is

suggested to the authorized operators to consider  the

use  of  individual  protection  devices  suitable  for

described activities.

During ordinary and extraordinary maintenance inter-

ventions,  where  it  is  required  to  remove  the  filter,

safety gloves are required.

i

Made in Italy

MONTORSO

XXXXXXX

Q min/max 

X/X

 m

3

/h

XXXXXXX

H max/min 

X/X

 m

IP 

XX

XXXX

/min

220∆/380Y V3~50Hz

cosø 

X

X/X

 A

XXXXXXXX

S1   l.cl. 

X

   

X

 kg

X

 kW   (

X

Hp)    S.F.

VICENZA

1

2

3

4

5

6

7

8

9 10

16
15

14

13

12

11

1 Pump type
2 Delivery
3 Head
4 Rated power
5 Tension nominale
6 Nom. motor current
7 Notes
8 Fréquence
9 Operation Duty
10 Insulation class
11 Weight
12 Power factor
13 Rotation speed rpm
14 Protection
15 Serial number
16 Certifications

GB

GXR, GXV Rev. 8 - Operating Instructions

Page 

3

IST GXR_10_2016Re8_MXS 11_03con gall  28/10/16  10:52  Pagina 9

Summary of Contents for GXR Series

Page 1: ...ubmersible Pumps Bombas sumergibles GXR GXV Page 2 English P gina 8 Espa ol ORIGINAL OPERATING INSTRUCTIONS INSTRUCCIONES ORIGINALES DE USO IST GXR_10_2016Re8_MXS 11_03con gall 28 10 16 10 52 Pagina 1...

Page 2: ...the understanding of the manual below are indicated the symbols used with the related meaning Information and warnings that must be observed otherwise there is a risk that the machine could damage or...

Page 3: ...Maximum permissible working pressure up to 60 m 6 bar 4 SAFETY 4 1 General provisions Before using the product it is necessary to know all the safety indications Carefully read all operating instructi...

Page 4: ...1 Stationary installation with vertical magnetic float switch Installation fit a check valve against back flow in the delivery pipe ball valve swing valve for GXR Provide for the possibility of removi...

Page 5: ...c power has been disconnected that the pump cannot be accidentally switched on and the impeller has stopped rotating completely The motors with supply current directly switched by thermally sensitive...

Page 6: ...ight pressure in the oil chamber Care must be taken to avoid a sudden spurting of oil Once the plug 34 08 with washer have been removed adjust the hole to the downward position and empty the chamber c...

Page 7: ...rload protection is set correctly see data on the engine indicator plate and make sure that the fuseboard upline of the engine has been properly connected 1c Check the power supply and make sure that...

Page 8: ...maci n y advertencias que deben respetarse si no causan da os al aparato o ponen en peligro la seguridad del personal Informaci n y advertencias de naturaleza el ctrica El incumplimiento con ellas pue...

Page 9: ...icas de comportamiento Antes de utilizar el producto es necesario conocer toda informaci n sobre la seguridad Es necesario leer cuidadosamente y seguir las instrucciones t cnicas de funcionamiento y l...

Page 10: ...magn tico Montar en el tubo de impulsi n una v lvula de reten ci n de bola y para GXR v lvula de clapeta Preveer que sea posible el movimiento de la bomba sin vaciar la instalaci n s es necesario inst...

Page 11: ...l ctrica por medio de interruptores t rmicos pueden arrancar autom ticamente No sacar nunca la bomba del agua cuando est todav a en funcionamiento Evitar en funcionamiento en seco Ejecuci n con interr...

Page 12: ...junta orientar el agujero hacia abajo y vaciar cuidadosamente la c mara No tirar el aceite usado al medio ambiente Sacando el tornillo 70 18 resulta inspeccionable el sello mec nico 36 00 Para el rel...

Page 13: ...del motor y asegurarse que la conexi n del cuadro el ctrico antes del motor se haya realizado correctamente ver placa del motor c Controlar que la alimentaci n el ctrica y asegurarse que el eje de la...

Page 14: ...ff Off On On h max h min Off On h max h min 3 93 037 3 min 250 x 250 H mm 265 300 300 h min h max 100 135 135 190 225 225 302 337 337 60 60 60 150 185 185 GXRM 9 GF GXRM GF GXRM GF GXRM 11 GF GXRM 13...

Page 15: ...135 135 190 225 225 5 6 2 6 7 GXR RM 1 kg 5 2 6 5 7 2 Off On min 350 x 350 70 340 G 1 ISO 228 1 4 3 93 037 4 h max h min 268 fM 3 93 037 3 4 93 553 fM 56 22 2 5 205 176 G 1 ISO 228 G 1 1 4 ISO 228 a 2...

Page 16: ...82 04 70 08 76 02 14 02 76 68 70 16 76 62 82 03 82 02 70 10 70 13 70 12 70 17 94 00 96 12 76 64 76 60 96 13 96 09 70 11 96 02 GXR 11 13 GXRM GXVM GXV 25 8 25 10 2 92 020 82 05 34 08 73 08 34 03 70 09...

Page 17: ...IDAD En CALPEDA S p A declaramos bajo nuestra exclusiva responsabilidad que las Bombas GXR GXV GXR R GXRM GXVM GXR RM modelo y numero de serie marcados en la placa de caracteristicas son conformes a l...

Reviews: