background image

THIS INSTRUCTION MANUAL IS THE PROPERTY

OF CALPEDA S.P.A. ANY REPRODUCTION, EVEN

IF PARTIAL, IS FORBIDDEN

SUMMARY

General information . . . . . . . . . . . . . . . . . . . . 8

TECHNICAL DESCRIPTION . . . . . . . . . . . . . 8

TECHNICAL FEATURES . . . . . . . . . . . . . . . . 9

4  

SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

5.

TRANSPORTATION AND HANDLING . . . . . 9

6.

INSTALLATION . . . . . . . . . . . . . . . . . . . . . . 10

7.

START-UP AND OPERATION . . . . . . . . . . . 11

MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . 11

DISPOSAL . . . . . . . . . . . . . . . . . . . . . . . . . . 12

10  SPARE PARTS. . . . . . . . . . . . . . . . . . . . . . . 12
11  TROUBLESHOOTING . . . . . . . . . . . . . . . . . 13
12  ANNEXES. . . . . . . . . . . . . . . . . . . . . . . . . . . 61
12.1  Dimensions and weights. . . . . . . . . . . . . . . . 61
12.2 Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Copy of the declaration of conformity . . . . . . . . . . 64

1 GENERAL INFORMATION

Before  using  the  product  carefully  read  the  informa-

tion contained in this instruction manual, the manual

should be kept for future reference.

Italian  is  the  original  language  of  this  instruction

manual,  this  language  is  the  reference  language  in

case of discrepancies in the translations.

This  manual  is  part  of  the  essential  safety  require-

ment and must be retained until the product is finally

de-commissioned.

The customer, in case of loss, can request a copy of

the  manual  by  contacting  Calpeda  S.p.A.  or  their

agent,  specifying  the  type  of  product  data  shown  on

the label of the machine (see 2.3 Marking)

Any  changes,  alterations  or  modifications  made  to  the

product or part of it, not authorized by the manufacturer,

will revoke the "CE declaration" and warranty.

This appliance should not be operated

by children younger than 8 years, peo-

ple  with  reduced  physical,  sensory  or

mental  capacities,  or  inexperienced

people  who  are  not  familiar  with  the

product,  unless  they  are  given  close

supervision  or  instructions  on  how  to

use it safely and are made aware by a

responsible  person  of  the  dangers  its

use might entail.

Children  must  not  play  with  the

appliance.

It  is  the  user's  responsibility  to  clean

and  maintain  the  appliance.  Children

should  never  clean  or  maintain  it

unless they are given supervision.

Do  not  use  in  ponds,  tanks  or  swim-

ming pools or where people may enter

or come into contact with the water.

Read  carefully  the  installation  section

which sets forth:

- The maximum  permissible structural

working pressure (Chapter 3.1).

- The  type  and  section  of  the  power

cable (Chapter 6.7).

- The type of electrical protection to be

installed (Chapter 6.7).

1.1 Symbols

To improve the understanding of the manual, below are

indicated the symbols used with the related meaning.

Information and warnings that must be observed,

otherwise there is a risk that the machine could

damage or compromise personnel safety.
The failure to observe electrical information and

warnings,  could  damage  the  machine  or

compromise personnel safety.
Notes  and  warnings  for  the  correct

management of the machine and its parts.

Operations that could be performed by the final

user. After carefully reading of the instructions,

is  responsible  for  maintenance  under  normal

conditions.  They  are  authorized  to  affect

standard maintenance operations.
Operations that must be performed by a qualified

electrician.  Specialized  technician  authorised  to

affect  all  electrical  operations  including

maintenance. They are able to operate with in the

presence of high voltages.
Operations  that  must  be  done  performed  by  a

qualified  technician.  Specialized  technician  able

to  install  the  device,  under  normal  conditions,

working during "maintenance", and allowed to do

electrical  and  mechanical  interventions  for

maintenance. They must be capable of executing

simple  electrical  and  mechanical  operations

related to the maintenance of the device.
Indicates that it is mandatory to use individual

protection devices.

Operations that must be done with the device

switched off and disconnected from the power

supply.

Operations that must be done with the device

switched on.

1.2 Manufacturer name and address

Manufacturer name: Calpeda S.p.A.

Address: Via Roggia di Mezzo, 39

36050 Montorso Vicentino - Vicenza / Italia

www.calpeda.it

1.3 Authorized operators

The  product  is  intended  for  use  by  expert  operators

divided  into  end  users  and  specialized  technicians.

(see the symbols above).

It's  forbidden,  for  the  end  user,  carry  out

operations  which  must  be  done  only  by

specialized  technicians.  The  manufacturer

declines any liability  for damage related to the

non-compliance of this warning.

1.4 Warranty

For  the  product  warranty  refer  to  the  general  terms

and conditions of sale. 

The warranty covers only the replacement and

the  repair  of  the  defective  parts  of  the  goods

(recognized by the manufacturer).

The  Warranty  will  not  be  considered  in  the  following

cases:

i

OFF

ON

i

i

GB

GXR, GXV Rev. 8 - Operating Instructions

Page 

2

IST GXR_10_2016Re8_MXS 11_03con gall  28/10/16  10:52  Pagina 8

Summary of Contents for GXR Series

Page 1: ...ubmersible Pumps Bombas sumergibles GXR GXV Page 2 English P gina 8 Espa ol ORIGINAL OPERATING INSTRUCTIONS INSTRUCCIONES ORIGINALES DE USO IST GXR_10_2016Re8_MXS 11_03con gall 28 10 16 10 52 Pagina 1...

Page 2: ...the understanding of the manual below are indicated the symbols used with the related meaning Information and warnings that must be observed otherwise there is a risk that the machine could damage or...

Page 3: ...Maximum permissible working pressure up to 60 m 6 bar 4 SAFETY 4 1 General provisions Before using the product it is necessary to know all the safety indications Carefully read all operating instructi...

Page 4: ...1 Stationary installation with vertical magnetic float switch Installation fit a check valve against back flow in the delivery pipe ball valve swing valve for GXR Provide for the possibility of removi...

Page 5: ...c power has been disconnected that the pump cannot be accidentally switched on and the impeller has stopped rotating completely The motors with supply current directly switched by thermally sensitive...

Page 6: ...ight pressure in the oil chamber Care must be taken to avoid a sudden spurting of oil Once the plug 34 08 with washer have been removed adjust the hole to the downward position and empty the chamber c...

Page 7: ...rload protection is set correctly see data on the engine indicator plate and make sure that the fuseboard upline of the engine has been properly connected 1c Check the power supply and make sure that...

Page 8: ...maci n y advertencias que deben respetarse si no causan da os al aparato o ponen en peligro la seguridad del personal Informaci n y advertencias de naturaleza el ctrica El incumplimiento con ellas pue...

Page 9: ...icas de comportamiento Antes de utilizar el producto es necesario conocer toda informaci n sobre la seguridad Es necesario leer cuidadosamente y seguir las instrucciones t cnicas de funcionamiento y l...

Page 10: ...magn tico Montar en el tubo de impulsi n una v lvula de reten ci n de bola y para GXR v lvula de clapeta Preveer que sea posible el movimiento de la bomba sin vaciar la instalaci n s es necesario inst...

Page 11: ...l ctrica por medio de interruptores t rmicos pueden arrancar autom ticamente No sacar nunca la bomba del agua cuando est todav a en funcionamiento Evitar en funcionamiento en seco Ejecuci n con interr...

Page 12: ...junta orientar el agujero hacia abajo y vaciar cuidadosamente la c mara No tirar el aceite usado al medio ambiente Sacando el tornillo 70 18 resulta inspeccionable el sello mec nico 36 00 Para el rel...

Page 13: ...del motor y asegurarse que la conexi n del cuadro el ctrico antes del motor se haya realizado correctamente ver placa del motor c Controlar que la alimentaci n el ctrica y asegurarse que el eje de la...

Page 14: ...ff Off On On h max h min Off On h max h min 3 93 037 3 min 250 x 250 H mm 265 300 300 h min h max 100 135 135 190 225 225 302 337 337 60 60 60 150 185 185 GXRM 9 GF GXRM GF GXRM GF GXRM 11 GF GXRM 13...

Page 15: ...135 135 190 225 225 5 6 2 6 7 GXR RM 1 kg 5 2 6 5 7 2 Off On min 350 x 350 70 340 G 1 ISO 228 1 4 3 93 037 4 h max h min 268 fM 3 93 037 3 4 93 553 fM 56 22 2 5 205 176 G 1 ISO 228 G 1 1 4 ISO 228 a 2...

Page 16: ...82 04 70 08 76 02 14 02 76 68 70 16 76 62 82 03 82 02 70 10 70 13 70 12 70 17 94 00 96 12 76 64 76 60 96 13 96 09 70 11 96 02 GXR 11 13 GXRM GXVM GXV 25 8 25 10 2 92 020 82 05 34 08 73 08 34 03 70 09...

Page 17: ...IDAD En CALPEDA S p A declaramos bajo nuestra exclusiva responsabilidad que las Bombas GXR GXV GXR R GXRM GXVM GXR RM modelo y numero de serie marcados en la placa de caracteristicas son conformes a l...

Reviews: