12.1

 

Dimensions and weights

Dimensions et poids

 

Dimensiones y pesos

GXR, GXV 25

fM

GXR GXRM

GXV GXVM

a

TYPE

kg

mm

265

300

300

360

375

375

400

420

450

230

265

265

310

325

325

350

370

400

5,2

6,5

7,2

12

12,5

12,5

15

16

17,5

fM

a

TYPE

kg

mm

302

337

337

267

302

302

h

max

340

340

340

380

395

395

420

440

470

h

max

375

375

375

h

min

70

70

70

255

270

270

295

315

345

DN Ø P

G 1

1/4

G 1

1/4

G 1

1/4

G 1

1/2

G 1

1/2

G 1

1/2

G 1

1/2

G 1

1/2

G 1

1/2

10

10

10

12

12

12

12

12

12

B

176

176

176

228

228

228

228

228

228

h

min

130

130

130

5,3

6,6

7,3

5

6,2

6,7

11

11,5

11,5

13

14,5

16

5,1

6,3

6,8

min 250 x 250

3.93.037/3

Off

Off

On

On

h

max

h

min

Off

On

h

max

h

min

3.93.037/3

min 250 x 250

H

mm

265

300

300

h

min

h

max

100

135

135

190

225

225

302

337

337

60

60

60

150

185

185

GXRM  9 GF

GXRM  ..GF

GXRM  ..GF

GXRM  11 GF

GXRM  13 GF

GXVM  25-6 GFA

GXVM  ..GFA

GXVM  25-8 GFA

GXVM  25-10 GFA

TYPE

4.93.388

fM

B

DN

ISO 228

ISO 228

a

fM

a

4.93.411

176

G 1 1/4

Ø 25

Ø P

GXR

(M)

  9

GXR

(M)

  11

GXR

(M)

  13

GXR

(M)

 12-10

GXR

(M)

 12-12

GXR

(M)

 12-14

GXR

(M)

 12-16

GXR

(M)

 12-18

GXR

(M)

 12-20

GXV

(M)

  25-6

GXV

(M)

  25-8

GXV

(M)

  25-10

min 300 x 300

3.93.037/3

On

Off

h min

h max

On

Off

h min

h max

GXRM 12-10 GF

GXRM 12-12 GF

GXRM 12-14 GF

GXRM 12-16 GF

GXRM 12-18 GF

GXRM 12-20 GF

360

fM

375

375

400

420

450

mm

a

310

325

325

350

370

400

4.93.602

MAX

MIN

287.5

min

180

195

195

220

240

270

max

270

285

285

310

330

360

h

h

h

max

h

min

fM

a

IST GXR_10_2016Re8_MXS 11_03con gall  28/10/16  10:53  Pagina 61

Summary of Contents for GXR Series

Page 1: ...ubmersible Pumps Bombas sumergibles GXR GXV Page 2 English P gina 8 Espa ol ORIGINAL OPERATING INSTRUCTIONS INSTRUCCIONES ORIGINALES DE USO IST GXR_10_2016Re8_MXS 11_03con gall 28 10 16 10 52 Pagina 1...

Page 2: ...the understanding of the manual below are indicated the symbols used with the related meaning Information and warnings that must be observed otherwise there is a risk that the machine could damage or...

Page 3: ...Maximum permissible working pressure up to 60 m 6 bar 4 SAFETY 4 1 General provisions Before using the product it is necessary to know all the safety indications Carefully read all operating instructi...

Page 4: ...1 Stationary installation with vertical magnetic float switch Installation fit a check valve against back flow in the delivery pipe ball valve swing valve for GXR Provide for the possibility of removi...

Page 5: ...c power has been disconnected that the pump cannot be accidentally switched on and the impeller has stopped rotating completely The motors with supply current directly switched by thermally sensitive...

Page 6: ...ight pressure in the oil chamber Care must be taken to avoid a sudden spurting of oil Once the plug 34 08 with washer have been removed adjust the hole to the downward position and empty the chamber c...

Page 7: ...rload protection is set correctly see data on the engine indicator plate and make sure that the fuseboard upline of the engine has been properly connected 1c Check the power supply and make sure that...

Page 8: ...maci n y advertencias que deben respetarse si no causan da os al aparato o ponen en peligro la seguridad del personal Informaci n y advertencias de naturaleza el ctrica El incumplimiento con ellas pue...

Page 9: ...icas de comportamiento Antes de utilizar el producto es necesario conocer toda informaci n sobre la seguridad Es necesario leer cuidadosamente y seguir las instrucciones t cnicas de funcionamiento y l...

Page 10: ...magn tico Montar en el tubo de impulsi n una v lvula de reten ci n de bola y para GXR v lvula de clapeta Preveer que sea posible el movimiento de la bomba sin vaciar la instalaci n s es necesario inst...

Page 11: ...l ctrica por medio de interruptores t rmicos pueden arrancar autom ticamente No sacar nunca la bomba del agua cuando est todav a en funcionamiento Evitar en funcionamiento en seco Ejecuci n con interr...

Page 12: ...junta orientar el agujero hacia abajo y vaciar cuidadosamente la c mara No tirar el aceite usado al medio ambiente Sacando el tornillo 70 18 resulta inspeccionable el sello mec nico 36 00 Para el rel...

Page 13: ...del motor y asegurarse que la conexi n del cuadro el ctrico antes del motor se haya realizado correctamente ver placa del motor c Controlar que la alimentaci n el ctrica y asegurarse que el eje de la...

Page 14: ...ff Off On On h max h min Off On h max h min 3 93 037 3 min 250 x 250 H mm 265 300 300 h min h max 100 135 135 190 225 225 302 337 337 60 60 60 150 185 185 GXRM 9 GF GXRM GF GXRM GF GXRM 11 GF GXRM 13...