User Manual - Rev AJ
California Instruments
FREQUENCY TRANSIENTS (Group 1 only)
Seq. No
Frequency
Time
1 400
5
Minute
2 440
150msec
3 400
5Sec.
4 350
150msec
5 400
5Sec.
Table 9-5: Normal Frequency Transient Sequence
This test applies to Group 1 only. At 115 voltage, change the frequency per sequence listed in
e test will cycle 5 times starting from sequence 2.
only)
Table 9-5. Th
FREQUENCY VARIATION (Group 2 and 3
Seq. No
Initial Frequency
Slew rate
Final Frequency
Group2 Group3
Hz/Sec
Group2 Group3
1
360 360
100
650 800
2
650 800
100
360 360
3
360
360
Pause 5 sec
360
360
Table 9-6: Normal Frequency Variation Sequence
This test will apply to Group 2 and 3 only. At 115 voltage, the frequency is set to 360Hz for 5
9.3.1.5.2 EMER
ST
From th
ENU sc
th
C entry
t
rsor
keys. Press the ENTER key to select the EMERGENCY screens. The screen will appear as
shown in Figure 9-8.
1
VOLT FREQ MIN
2
VOLT FREQ MAX
3 VOLT
UNBALANCE
The above tests can be selected by scrolling to the highlighted selection using the up and down
key and the ENTER key to start the selected test.
minutes. The frequency is slowed per sequence listed in Table 9-6. The test will cycle 3 times.
The frequency will return to nominal after the test is completed.
GENCY TE
DO160 M
e
roll to e EMERGENCY A
using he up and down cu
Figure 9-8: Emergency Screen
The EMERGENCY SCREEN has the following tests:
MX Series
199