User Manual – Rev AJ
California Instruments
WAVE GR
[3P
i Controller only
] Sets the user defined waveform group tha
will be loaded at power on
OUP
t
. Available groups are 0, 1, 2 and 3.
Each group can contain up to 50 user-defined waveforms. A
waveform group can only be loaded at power up. To change
groups, you must change this field to the desired new group
CLOCK MODE
NO. OUTPUT
phase mode (LAST). If
VOLT ALC
system
tion and accuracy.
and cycle the power to the AC source or issue a *RST
command over one bus.
Sets the clock source used at power up. Available settings are
Stand Alone (STAND), MASTER (-LKM clock and lock master),
and AUX (-LKS clock and lock auxiliary).
[
MX30-3Pi or MX45-3Pi model only
] Sets the phase mode at
power up. Available options are single-phase mode (ONE),
three-phase mode (THREE) or last used
the phase mode option is not installed, this field is fixed to ONE
or THREE.
Determines ALC mode at power on. The ALC mode adjusts the
output voltage based on internal voltage measurement
and provides enhanced output regula
Available settings are ON, OFF or REG (Series II only).
112 MX
Series