Software Specification
Module
V. MacID
XV. BIOS
V.1 Baud Rate
Program Number
I.
Version
DVC10
10
125K
SA2278220
3.41
DVC22
22
3.41
125K
NA
DVC41
41
3.41
125K
NA
DVC41
42
3.41
125K
NA
A. EE-Memory Defaults:
‘// Pulses per Yard traveled (6 for J1939, 30 for Radar)//
=3
//
0
er //
0
trol loop //
00
A – Circulate
3 eeCleanCWrevsB=10
nOut revolutions to turn CW step B –
14. eeCleanCW_RPMa=200
uction //
8 eeCleanOpenBarT2=4000
Out time (ms) to Open Bars //
lts //
te Entry (5 = 0.05 gal/sq.yd.) //
S=0
1. eePulsesPerFT=6
2. eePulsesBetBars=2
‘// The number of pulses between the two bars //
3. eeAsphaltPumpPPR
0
‘// Pulses Per Rev on the asphalt pump //
4. eeGallonRatio=100
‘// Ratio for gallons, 100 = 1 to 1 //
5. eeFootRatio=100
‘// Ratio for distance, 100 = 1 to 1 //
6. eeTotalYards=0
‘// Working Yards Traveled Totalizer
7. eeTotalSQyards=
‘// Square Yards of material used Totaliz
8. eeTotalGallons=0
‘// Gallons of material used totalizer //
9. eePumpRPM_DB=
‘// Deadband for the Pump RPM PI con
10. eePumpRPM_Pgain=20
‘// Pgain for the Pump RPM PI control loop //
11. eePumpRPM_Igain=150
‘// Igain for the Pump RPM PI control loop //
12. eeCleanCWrevsA=300
‘// Auto-CleanOut revolutions to turn CW step
Solvent //
1 .
0
‘// Auto-Clea
Dump Solvent back into the Solvent Tank //
‘// Auto-CleanOut RPM to turn CW step A //
15. eeCleanCW_RPMb=200
‘// Auto-CleanOut RPM to turn CW step B //
16. eeCleanCCW_RPMa=350
‘// Auto-CleanOut RPM to turn CCW – Rev S
17. eeCleanSuckBarT1=30000
‘// Auto-Cleanout time (ms) to Rev-Suck the Bar before
opening //
1 .
‘// Auto-Clean
19. eeCleanShutBarT3=4000
‘// Auto-CleanOut time (ms) to Shut Bars //
20. eeLTbarMinInch=48
‘// LT bar retracted width //
21. eeLTbarMaxInch=96
‘// LT bar extended width //
22. eeRTbarMinInch=48
‘// RT bar retracted width //
23. eeRTbarMaxInch=96
‘// RT bar extended width //
24. eeLTbarDeadband=8
‘// LT bar extended width //
25. eeRTbarDeadband=8
‘// RT bar extended width //
26. eeLTbarMinVolts=1023
‘// LT bar sensor Min Cal Vo
27. eeLTbarMaxVolts=0
‘// LT bar sensor Max Cal Volts //
28. eeRTbarMinVolts=1023
‘// RT bar sensor Min Cal Volts //
29. eeRTbarMaxVolts=0
‘// RT bar sensor Max Cal Volts //
30. eeTravelDist=100
‘// Distance to Spray //
31. eeSpecRoadWidth=0
‘// Special Road-Width //
32. eeAppRateMan=10
‘// Manual Application Ra
33. eeAppRatePre1=2
‘// Preset Application Rate #1 (5 = 0.05 gal/sq.yd.) //
34. eeAppRatePre2=5
‘// Preset Application Rate #2 (5 = 0.05 gal/sq.yd.) //
35. eeAppRatePre3=8
‘// Preset Application Rate #3 (5 = 0.05 gal/sq.yd.) //
36. eeAppRatePre4=10
‘// Preset Application Rate #4 (5 = 0.05 gal/sq.yd.) //
37. eeAppRatePre5=15
‘// Preset Application Rate #5 (5 = 0.05 gal/sq.yd.) //
38. eeAppRatePre6=20
‘// Preset Application Rate #6 (5 = 0.05 gal/sq.yd.) //
39. eeAppRatePre7=30
‘// Preset Application Rate #7 (5 = 0.05 gal/sq.yd.) //
40. eeAppRatePre8=35
‘// Preset Application Rate #8 (5 = 0.05 gal/sq.yd.) //
41. eeAppRate=9
‘// Memory of Application Rate selected //
42. eeMetric_or_U
‘// Units, 0=US, 1=Metric //
Calder Brothers Corporation
Model: Precision Spray
Serial #
944-N-P2C---S-D00000 to Current
Page55
V2.2