Fault Codes for DVC10 Status LED
Blink Code
Reason f
ction
or Fault
Corrective A
·
1
Input Stop Fault
Critical input fault causing the
controller to disable all outputs
· ·
2
One of the Asphalt Valves has
Faulted
Check DVC41-1 and DVC41-2
controller lights
· · ·
ump Potentiometer
potentiometer, must
3
Asphalt P
signal out-of-range
Check wires and
be a 10K ohm pot with 1K ohm end-
resistors
· · · ·
Left Bar Sensor out-of-range
res and potentiometer, must
4
Check wi
be a 10K ohm pot with 1K ohm end-
resistors
· · · · ·
Right Bar Sensor out-of-range
res and potentiometer, must
5
Check wi
be a 10K ohm pot with 1K ohm end-
resistors
· · · · · ·
DVC22 is not communicating
N cable and connector
6
Check CA
· · · · · · ·
DVC41 is not communicating
Check CAN cable and connector
7
(DVC41 with MacID of 41)
· · · · · · · ·
Check CAN cable and connector
8
DVC41 is not communicating
(DVC41 with MacID of 42)
· · · · · · · · ·
t-
This will occur when the Asphalt
t
9
Asphalt Pump RPM sensor ou
of-range
pump is not turning. If the Asphal
pump is turning then check the RPM
sensor and wires