Detailed
Message
Code Reasons
Solutions
RAPID HEAT
RISE
154
Midway during charge the
temperature rose too rapidly
(more than 2°C in 2
minutes). Program stops
until battery is cooled by
5°C and then resumes. A
WAIT code may appear for
the battery to cool before
the next process begins.
Wait until processing is
complete. Lower the charge
rate in the extended C-code.
Observe battery performance.
The battery may be old.
READY
5 Service has completed and
battery is ready. Final
capacity or state-of-health is
displayed.
Faults or warnings (if any)
were corrected. Remove
battery and use as normal.
RECONDITION
TIMEOUT
146
Recondition time has
exceeded the expected
value for the battery.
Program goes to the next
cycle.
Verify the mAh settings on the
C-code.
Raise the recondition
discharge rate, (see
Recondition
Discharge Rate
,
page 53).
The battery may be
intrinsically safe, preventing
deep discharge. Use I/S
settings for the battery, (see
Intrinsically Safe Batteries
,
page 60)
If battery is new or has been
in storage, use the Prime
program.
Cells may be mismatched, run
the Prime program.
Monitor the battery use.