Problem
Possible Reasons or Solutions
Single cell gives inconsistent
results.
Calibrate the station, (see
To calibrate an
adapter
, page 113).
Set the charge method in the extended C-
code to DC Charge (for low terminal
voltage).
Single cells are discharging or charging too
quickly. Lower the discharge and charge
rates to 0.2 C.
Temperature is not displayed on
the detailed station screen during
service
Turn on the temperature sensing in the C-
code, (see
, page
Text is too large for the label.
Power off and power on the attached printer.
Analyzer does not respond to
input and there is continuous
beeping
Incomplete boot or power failure during in
boot up. Remove the adapters and restart
the analyzer.
No sounds are heard.
on
Manual Updates and Other References
The Cadex website is an additional resource for information about Cadex products.
Visit
for:
•
Product specifications and technical information
•
Articles
•
FAQ
•
Battery Adapter catalog
•
User manual and firmware version updates
For more information about rechargeable batteries,
Batteries in a Portable World
(second edition) is an authoritative and popular reference book. Written by Isidor
Cadex Electronics Inc. C7000-C Series Battery Analyzers
.
120
Summary of Contents for C7200
Page 2: ......
Page 138: ...Cadex Electronics Inc C7000 C Series Battery Analyzers 122...