IDROSTUFE A PELLET
38
Fig. 85 - back panel
8
SPECIAL MAINTENANCE
8.1
INTRODUCTION
For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs.
• Fume outlet pipes (fume c chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an autho-
rized technician in compliance with local regulations, with the instructions of the manufacturer and those of your insurance
company.
• It is also necessary to have the combustion chamber, motors and fans cleaned and to have the gaskets and the electronical
elements checked at least once a year.
All these operations must be planned in time with your Autorized Technical Assistance Service.
• After a long ineffective time, before turning on the stove check if there are obstructions in the fume exhaust.
• If the stove had been using continuously and intensely, the whole system (chimney included), must be cleaned and checked
more frequently.
• In case of replacement of damaged pieces please ask for the original spare part at the Autorized Retailer.
8.2
FUME CONDUIT CLEANING
The exhaust system must be cleaned every 2/3 months.
Fig. 86 - Fume conduit cleaning
• Remove the inspection lid of the T-union (see
Fig. 86
).
• Extract the ash which has accumulated in the inner.
• After cleaning repeat the operation in reverse order, checking the condition and efficiency of the gasket, and if necessary
replace it.
Summary of Contents for AQUOS3 16