31
IDROSTUFE A PELLET
Hardness of water circulating in the system, to prevent problems of incrustation and limescale, especially in
the domestic water heat exchanger. (> 25° French).
Installation of a water softener (if water hardness exceeds 25° French).
Filling the system with treated water (demineralised).
Possibly providing an anti-condensation circuit.
Installation of hydraulic shock absorbers to prevent water hammering along the fittings and pipes.
If you have very extensive systems (with a large amount of water) or which require frequent refilling, the installation of water
softening systems.
It should be remembered that incrustations drastically reduce performance due to their extremely low thermal
conductivity.
7.12 SYSTEM CONFIGURATION
Upon installation, the product must be set according to the type of system, selecting the appropriate parameter in the “SETTINGS”
menu.
The possible configurations are 5, as described below:
CONFIGURA-
TION
DESCRIPTION
1
Room temperature management via probe on the stove or by enabling an external room thermostat.
2
2.1 Room temperature management via probe on the stove or by enabling an external room thermostat:
instantaneous DHW production with plate exchanger.
2.2 Room temperature management via probe on the stove or by enabling an external room thermostat;
DHW production for boiler or storage tank with thermostat (optional).
DISCONNECT ANY 3-WAY VALVES AND INTERNAL FLOW SWITCHES
3
Room temperature management via probe on the stove or by enabling an external room thermostat; boiler
DHW production with ntc probe (10 kΩ ß3435).
DISCONNECT ANY 3-WAY VALVES AND INTERNAL FLOW SWITCHES
4
External Puffer management controlled by thermostat.
5
External Puffer management controlled by ntc probe (10 kΩ ß3435).
7.13 SYSTEM WITH: DIRECT VENT PELLET STOVE AND ROOM PROBE
Settable settings
SETTING
VALUES
ROOM TEMP.
5°C - 35°C
WATER TEMP.
30°C - 80°C
Parameters to set
SETTING
VALUES
Configuration
1