IDROSTUFE A PELLET
44
PROBLEM
CAUSE
SOLUTION
INTERVENTION
Stove running and
display showing
"Smoke Overtepe-
rature"
Reached fume
outlet limit tempe-
rature
The stove runs at minimum. NO PROBLEM!
The smoke extrac-
tion motor is not
working
No power to the
boiler
Check the mains voltage and the protective fuse
The motor is
broken
Check the motor and capacitor and, if necessary, replace them
The motherboard
is defective
Replace the electronic board
The control panel is
broken
Replace the control panel
The stove's smoke
duct produces
condensation
Low smoke tempe-
rature
Check that the flue is not clogged.
Increase stove power to minimum (pellet drop and fan revs).
Install condensation collection cup.
Stove running and
display showing
"SERVICE"
Routine main-
tenance alert (it
does not block the
system)
When this flashing message appears upon start-up, it means
that the preset operating hours have elapsed before mainte-
nance. Contact the service centre.
Summary of Contents for AQUOS3 16
Page 54: ...NOTE ...
Page 55: ...NOTE ...