IDROSTUFE A PELLET
42
PROBLEM
CAUSE
SOLUTION
INTERVENTION
Auger blocked by a
foreign object (for
example nails)
Clean the auger.
The auger geared
motor is out of
order
Replace the geared motor.
Check if on the
display there is an
"ACTIVE ALARM"
Have the stove checked.
The fire extinguish
and the stove stops
Empty hopper
Full the hopper.
Auger blocked by a
foreign object (for
example nails)
Clean the auger.
Bad quality pellets Try other types of pellets.
Pellet drop value
too low "phase 1" Adjust the pellet loading.
Check if on the
display there is an
"ACTIVE ALARM"
Have the stove checked.
The pellet tempe-
rature safety probe
has tripped
Let the boiler cool down, reset the thermostat until the
problem is resolved, then switch the boiler back on; if the
problem persists, contact customer service
The door does not
close perfectly or
the gaskets are
worn
Close the door and have the gaskets replaced with other
original ones
Unsuitable pellets Change the type of pellets with one that is recommended by
the manufacturer
Broken or defective
manostat
Replace the manostat
Ignition step is not
completed
Repeat ignition
Temporary power
outage
Wait for automatic restart
Summary of Contents for AQUOS3 16
Page 54: ...NOTE ...
Page 55: ...NOTE ...