12
SmartStack SSIM-A2-01/SSIM-A8-01
Installation
LEDs
There are four LEDs on the front panel of the SSIM-Ax-01 module. The LEDs
show the module status and activity. Table 2 explains the status LEDs on the left of
the module front panel, and Table 3 explains the ATM interface LEDs on the right
of the module front panel.
Table 4 shows the LED status for the SSIM-Ax-01 module under normal operating
conditions.
LED
Position
State
Meaning
DIAG (green)
Top
On
Diagnostics are in progress
Off
No diagnostics are in process
ERR (yellow)
Bottom
On
A module failure has
occurred
Off
The module is working
correctly
Table 2. Status LEDs and their Meanings
LED
Position
State
Meaning
RXSYNC (green)
Top
On
The ATM interface is
receiving a signal
Off
The ATM interface is not
attached to a live transmitter
SIGLOSS
(yellow)
Bottom
On
The ATM receive signal is
below an acceptable level
Off
The ATM receive signal is
acceptable
Table 3. ATM Interface LEDs and their Meanings