4-44 SmartCell ZX-250 User Guide
Performing Hardware Maintenance
Switch Administration
>
"•mamV
At this point, you have direct access to the power bus of the backplane, which
carries potentially hazardous voltage. DO NOT insert hands into the power
supply opening. DO NOT touch the backplane. DO NOT insert any metal (or
conductive) objects into the power supply opening.
–•
Replace the power supply with a new power supply module or with the sheet metal blank.
%
"¤›apm
If you do not replace the power supply module, you MUST install the sheet
metal blank in its place. Failing to do so affects the fan’s airflow and may cause
overheating and component failure. You also must replace the blank to maintain
EMI integrity.
4.9.15
Replacing a Fuse
Use the following instructions to replace a spent fuse.
s•
Turn the power switch to off, and remove the power cord.
¢•
Access the fuse assembly (part of the power plug assembly) in the back of the switch.
••
With a flat-blade screw driver, gently pry out the plastic fuse assembly (see Figure 4-17).
Figure 4-17 Pry out the fuse assembly.
ZX-250 and ZX-250i
ZX-250r
Summary of Contents for SmartCell ZX-250
Page 12: ...xii SmartCell ZX 250 User Guide Table of Contents...
Page 16: ...xvi SmartCell ZX 250 User Guide List of Tables...
Page 18: ...1 2 SmartCell ZX 250 User Guide Introduction...
Page 46: ...3 8 SmartCell ZX 250 User Guide Creating an Emulated LAN IP Over ATM and LANE...
Page 92: ...4 46 SmartCell ZX 250 User Guide Performing Hardware Maintenance Switch Administration...
Page 98: ...5 6 SmartCell ZX 250 User Guide Troubleshooting Congestion Troubleshooting...
Page 110: ...A 12 SmartCell ZX 250 User Guide Acronyms...
Page 124: ...C 8 SmartCell ZX 250 User Guide Managing the SmartCell ZX 250 Agent Support...