51
EN
12 Technical data
Softening unit
Type
BWT Perla hybrid
Nominal connection width
DN
32
Connection type
G 11/4"
Nominal capacity in accordance with DIN EN 14743
min./max.
mol (m³ x °dH)
1.6 (9)/3.2 (18)
Capacity/kg of regenerative salt in accordance with
DIN EN 14743 min./max.
mol
4.2 / 6.1
Peak flow with closed blending
m³/h
See diagram of
peak flow
Peak flow when blending from 20°dH to 0°dH
m³/h
1.7
Nominal flow in accordance with DIN EN 14743
m³/h
1.7
Nominal pressure PN
bar
10
Min./max. operating pressure
bar
2 to 8
Pressure drop at operating flow
bar
1.0
Area of application according to DIN 1988-200
Residential units
People
1 – 5
2 – 12
Ion exchange material fill quantity
l
6.2
Supply of regenerative, max.
kg
32
Regenerative consumption per
100% regeneration, min./max. approx.
kg
0.26 / 0.76
Rinsing water consumption per
100% regeneration at 4 bar, min./max. approx.
l
32 / 40
Rinsing water flow rate, max.
l/h
200
Regeneration time for
100% regeneration, min./max. approx.
min.
45 / 50
Water temperature, min./max.
°C
5 to 25
Ambient temperature, min./max.
°C
5 to 40
Humidity
Non-condensing
Power supply
V/Hz
230/50 – 60
Unit voltage
VDC
24
Connected load during operation, max.
W
5.6
Power during regeneration, max.
W
40
Fault message output, max.
VDC / A
24 / 0.5
Protection class
IP54
Operating weight if filled to max.
kg
76
Shipping weight, approx.
kg
32
Production number
PNR
6-501305