31
EN
AQA Guard / AQA Stop Wireless
When using BWT wireless humidity sensors, they
must be connected to the product in the “External
modules” menu.
Water hardness
To change the water hardness, press
ENTER VALUE
MANUALLY
>
The adjustment of the motor blending of the product
should ideally be carried out at a volume flow of
400 to 600 l/h. First of all, measure the hardness
of the pearl water at the nearest fully opened tap
downstream from the product. Compare this value
with the value in the control unit and, if necessary,
adjust it, i.e. increase or reduce the hardness.
NOTE
►
The water hardness cannot be adjusted
during a regeneration procedure.
Setting actor blending
If the outlet water hardness deviates, it can be finely
adjusted in the “Setting blending of motors” screen.
The impulse value within the gear wheel corre-
sponds to fully opened blending. The value below
the gear wheel reflects the current position of
blending.
After adjusting your setting, press
SAVE