BWT Perla hybrid Installation And Operating Manual Download Page 1

1-510878 / 

12788

 / 2020-01 / © BWT

 W

assertechnik GmbH / Printed in Germany

BWT Perla hybrid

Simplex softening unit

Subject to change without notice!

Installation and operating manual EN

Summary of Contents for Perla hybrid

Page 1: ...1 510878 12788 2020 01 BWT Wassertechnik GmbH Printed in Germany BWT Perla hybrid Simplex softening unit Subject to change without notice Installation and operating manual EN...

Page 2: ...2 Thank you very much for the confidence that you have shown in us by purchasing a BWT appliance EN Table of contents Page 3...

Page 3: ...metering substance container 18 7 Start up 20 7 1 Display and operation 20 7 2 Starting up 20 8 Operation 26 8 1 Opening the Easy Fill technology cover 26 8 2 Closing the Easy Fill technology cover 26...

Page 4: ...otential dan gers that may arise while operating the product 1 2 Scope of the documentation This documentation applies exclusively to the product whose production number is listed in chapter 12 Techni...

Page 5: ...y flat and has a sufficient load bear ing capacity It must be secured so that it does not fall or tip over 1 5 Symbols used This symbol indicates general risks to persons equipment or the environment...

Page 6: ...s Hazard prevention measure Explains how to avoid the hazard Signal word Colour Severity of the hazard DANGER High risk hazard Indicates a hazardous situation which if not avoided will result in death...

Page 7: ...rnamental lakes aquariums or fish ponds Handing over the product to the operator If there is a delay between in stallation start up of the unit and transfer to the operator both exchanger columns must...

Page 8: ...n and operating manual contact the BWT drinking water specialist or fitter Quality of the regen erative Impurities from cheaper regener atives with insoluble components cause deposits UseofBWTPerlatab...

Page 9: ...ter inlet with non return valve 7 Column containing ion exchanger material 11 Proximity sensor 12 Mineral substance metering device Bewados INT 13 Suction lance with level monitoring dry running prote...

Page 10: ...s Order no BWT Bewasol brine lifting system 11808 BWT AQA Guard moisture sensor required accessories for the AQA Guard function 11772 LTE antenna cable length of 3 m 1 444528 Fault signal cable ZLT 1...

Page 11: ...fied in this manual The use of unauthorised consumables and spare parts 3 3 Other applicable documentation Data protection notice Material safety data sheets Installation and operating manual for the...

Page 12: ...consumption dependent This adaptive sequential design maximises sof tened water availability and minimises stagnation During the regeneration process untreated inflow water is available The regenerati...

Page 13: ...tion The programmed parameters are stored perma nently and remain unaffected by this AQA Watch function Very small volume flows 60 l h over a longer period of time 10 minutes indicate a problem in the...

Page 14: ...akage from the softening unit if the product is damaged The rated mains power 230 V 50 Hz and the required operating pressure must be present at all times A separate means of protection against a shor...

Page 15: ...m of the device 5 5 Installation The pipeline network must be rinsed before the product can be installed Use corrosion resistant pipe materials for instal lation Pay attention to corrosion causing che...

Page 16: ...ect this to the inflow water connection IN 6 of the product Observe the arrow indicating the direction of flow Connect a corrugated hose to the Multiblock X inlet and then connect this to the outlet w...

Page 17: ...n accordance with the installation instructions enclosed with the siphon In accordance with EN 1717 the rinsing water and overflow hoses must be connected to the sewage system at least 20 mm above the...

Page 18: ...rom one container to another Damaged or soiled additive containers must not be used Observe the use by date on additive containers Remove the suction lance A from the product Remove the aluminium seal...

Page 19: ...EN Ensure that the additive container is correctly inserted and the connection hose and cable s are not kinked or twisted Close the Easy Fill technology cover by press ing down until it snaps into pla...

Page 20: ...up Adding regenerative Open the Easy Fill technology cover 2 and add up to 30 kg of regenerative regenerative tablets in accordance with DIN EN 973 type A to the regen erative container 3 NOTE The pr...

Page 21: ...To do so press SKIP Following screen Installation check 1 4 Installation check 1 4 Check the waste water hoses are connected properly Press INSTALLED Following screen Connection on the Multiblock Ins...

Page 22: ...o not pour water into the device Press CONFIRM Following screen Installation check NOTE When filling the regenerative make sure that no dirt gets into the locking mecha nism red circle Installation ch...

Page 23: ...ypad is displayed Enter your e mail address in the text field NOTE If the registration was unsuccessful please wait one hour and then try again To successfully register complete the steps described in...

Page 24: ...screen Set the water hardness Water hardness The value of the inflow water hardness is entered from a database Check the database value corre sponds to the water hardness at the installation site If...

Page 25: ...n Following screen Status overview Status overview Start up is complete The product is ready for use After filling it may take until the next regeneration to update this value Range of coverage in day...

Page 26: ...tus display 8 1 Opening the Easy Fill technology cover Easy Fill technology cover with handleless tip on function To open tap lightly on the white area of the housing above the status display The Easy...

Page 27: ...w and the display All commonly avail able regeneratives that comply with DIN EN 973 type A e g Perla tabs can be used Press gently to open the Easy Fill technology cover Fill the regenerative containe...

Page 28: ...a new mineral substance container BWT Smart Mineral at the ready When the mineral substance is depleted a mes sage appears on the screen Mineral substance container empty To change the mineral substan...

Page 29: ...Fill operating materials Additive The softener and the metering pump resume operation NOTE Observe the safety data sheets of the metered substance Only original BWT additives may be used Additives mu...

Page 30: ...functions can be activat ed or deactivated here AQA Stop Sensor If the product s floor sensor detects water on the floor the water supply downstream of the product is shut off and a warning issued Th...

Page 31: ...water at the nearest fully opened tap downstream from the product Compare this value with the value in the control unit and if necessary adjust it i e increase or reduce the hardness NOTE The water ha...

Page 32: ...ialist or operator instructed person according to section 1 3 and tap the corresponding field NOTE No maintenance can be performed dur ing the regeneration procedure Routine maintenance Press START Yo...

Page 33: ...w the instructions for its use Checking the water inflow In this step you check whether flow and consump tion are correctly recognised by the product Allow water to flow at a tap Cleaning In this step...

Page 34: ...eaning process the oper ating display appears Shutting down the unit To shut down the unit e g after a long period of absence press START You will be asked to close the Multiblock The product is then...

Page 35: ...ct type device ID serial number commissioning date and software versions can be found in the Device info menu item Flow volume Here you can see a time related evaluation of the flow rates Serial no PN...

Page 36: ...e status Here you will find further information about your product Contact person In the Contact Persons menu you can find contact details for the contact persons e g the fitter and after sales servic...

Page 37: ...ck Regenerate both exchanger columns Then open all taps to rinse the system 1 to 6 months Close the Multiblock and shut down the product Open the main shut off valve and the Multiblock Have BWT after...

Page 38: ...o date messages directly to your smartphone using the BWT Best Water Home app User registration Tap inside the text box A keypad is displayed Enter your e mail address in the text field Note If the re...

Page 39: ...Enter the postcode of the installation location of your product Press CONTINUE Following screen Entering the region Entering the region If necessary select your region in the menu After making your s...

Page 40: ...your BWT product into a home network via LAN RJ45 Ethernet connection 15 or WLAN 9 2 LAN connection LAN connection to the home network via an existing router Connect the LAN socket 15 of the BWT prod...

Page 41: ...s pos sible using either LAN or WLAN It is not possible to have two connections at the same time To enable data transfer the follow ing port must be open on your router TLS SSL port 443 9 4 Activating...

Page 42: ...are available on request NOTE The product data is not displayed in real time Installation of the BWT Best Water Home app Launch the Apple App Store or Google Play store on your mobile device and sear...

Page 43: ...192 168 110 1 displayed under Info Serial no PNR in the address bar The login window of the BWT product appears Enter the login code that you received from BWT by e mail NOTE If a field opens with a s...

Page 44: ...1 Were all mandatory fields completed Make sure the Title Surname and E mail address fields are complete If all fields are completed cor rectly please follow step 1 2 1 2 Is the product connect ed to...

Page 45: ...these periods activation is not possible Please try again after the specified maintenance period 3 3 Website opens with a fault message service request not available any longer To guarantee security...

Page 46: ...WT partner Use of partner services is only possible in collaboration with a BWT partner 4 Fault after suc cessful start up 4 1 Product does not yet show in the Settings Registration menu that the regi...

Page 47: ...ired 2 2 Product is not displayed Did you activate the product successfully You will receive the e mail confirming successful acti vation after completion of the activation process If this is not the...

Page 48: ...functionality and fulfil the warranty conditions 10 1 Intended operation The intended operation of the product includes start up operation decommissioning and if nec essary recommissioning Intended op...

Page 49: ...ired Check for leaks visual inspection Every 2 months Required Required Functional test control unit display Every 2 months Required Not required Test regenerative consumption depending on the treated...

Page 50: ...valve 5 1 Sieve base 5 2 Low salt gauge 5 3 Brine level switch 6 1 AQA Stop floor sensor 6 2 BWT AQA test 10 5 Replacement of parts The operator must ensure that parts that are subject to wear and age...

Page 51: ...according to DIN 1988 200 Residential units People 1 5 2 12 Ion exchange material fill quantity l 6 2 Supply of regenerative max kg 32 Regenerative consumption per 100 regeneration min max approx kg 0...

Page 52: ...797 Width B mm 394 Depth C mm 505 Water inlet connection height D mm 592 Water outlet connection height E mm 652 Overflow connection height F mm 410 Clearance to allow the device cover to be opened G...

Page 53: ...duct s outlet water hardness value is reduced to values less than 10 of the inflow water hardness for at least 10 minutes The pressure difference may rise to greater than 1 bar Operating flow is the f...

Page 54: ...dness still has to be finely adjusted Reset the water hardness and perform fine adjustment No water flow Water supply shut off by AQA Stop Check the installation for leaks Reset the AQA Stop The produ...

Page 55: ...atteries Batteries may not be disposed of in household waste under any circumstances Batteries not sealed inside the device must be removed and brought to a suitable collection point such as your deal...

Page 56: ...eam of the product m3 Water hardness upstream l downstream of the product dH Increase in sodium content of drinking water Water hardness upstream l downstream x 8 2 mg mg Regenerative refilled kg l x...

Page 57: ...e concentration of your water approx mg l Max permitted addition in accordance with the German Drinking Water Ordinance 2 2 mg l calculated as P Metering to set the pH value For minimising the corrosi...

Page 58: ...58...

Page 59: ...implex syst mes d adoucissement d eau Typ Type Type BWT Perla Baureihe series s rie de mod les ist entwickelt konstruiert und gefertigt in bereinstimmung mit den oben genannten Richtlinien in alleinig...

Page 60: ...5310 Mondsee Austria Phone 43 6232 5011 0 Fax 43 6232 4058 E mail office bwt at BWT Wassertechnik GmbH Industriestrasse 7 69198 Schriesheim Germany Phone 49 6203 73 0 Fax 49 6203 73 102 E mail bwt bwt...

Reviews: