Maintenance and inspection
Butzbach GmbH Industrietore
Original operating manual sliding doors_V1
13/01/2021
40
Qualified professionals must make their assessment objectively, from the perspective of workplace safety,
while not being influenced by other circumstances, e.g. financial circumstances.
9.1.4 Annual testing
ASR A1.7 specifies that the annual testing is to be performed by a qualified professional. The corresponding
professional knowledge by the people tasked with the testing guarantees proper testing of the system.
Evidence must be kept that the testing was completed, which is to be continuously attached to the testing log.
9.2
Maintenance and inspection work
Butzbach hangar doors and their components are designed for a
long useful life
(10 years or 10,000 cycles),
with respect to the functioning and performance characteristics.
Besides proper use, a requirement for this is a
regular inspection
/ testing and maintenance
in accordance with the inspection and maintenance plan
.
Some of the components are
consumable parts
and may have a shorter useful life accordingly.
Consumable parts must be replaced either after the determined
number of cycles
/ time or depending
on their state (determined during inspection).
The replacement of the POM and Vulkollan rollers in the upper guiding system of the door leaf must
occur after 8 years at the latest.
Inspection / testing of the door system
must take place at least
once a year
.
Noticeable damage to the door system must be immediately notified to the
service department
or fixed.
The system is equipped with devices that serve to ensure the safety and protection of operating personnel.
Therefore, the safety devices and components must be checked regularly.
9.2.1 Inspection of safety components
Components
Instructions
Frequency
Safety components
Main switch
Turn the switch to the ON and OFF position.
Quarterly, at least annually
EMERGENCY STOP
button
Engage and disengage the button
Quarterly, at least annually
Safety edge control
Activate the closing edge of a door leaf during
operation: the closing edge of this door leaf
functions property if the drive unit immediately
switches off, the movement of the door leaf
stops and the door leaf reverses (goes in the
opposite direction).
Also perform this functional test on the other
door leaves.
Quarterly, at least annually
Closing edge signal
(remote control
batteries)
If present, we recommend that the batteries for
the signal transmission to the closing edge be
changed annually: unscrew and remove the
cover, then change both batteries.
Annually
Escape / exit sign
lighting
If present, test the functionality. Follow the
specifications of the workplace directive when
doing so!
Daily
Sensors
Functional test: test whether the sensor
responds by placing objects in the sensor range.
Quarterly, at least annually