Keep the taps open until the water flowing out of the taps has no bubbles
in it. This is the only way to ensure that the boiler is full of water.
Close all water taps.
Emptying the boiler:
Set the rotary switch (Fig. 156,3) on the operating unit (Fig. 156) to " "
(Fig. 156,4) or the flip switch (Fig. 157,1) to " ".
Turn knob (Fig. 156,1) anticlockwise until it can go no further.
Open all boiler drain cocks. To do this, position the rocking lever
(Fig. 158,1) vertically or turn the cap (Fig. 158,2) in an anticlockwise direc-
tion.
Check whether the water has been drained completely from the boiler
(approx. 12.5 litres).
9.4.3
Hot water source (partially special equipment)
The hot water source can either be operated using the 230 V power supply
(electrical mode of operation), with the hot air of the heater system or both
types of energy. The hot water source heats approx. 5 l water to a temperature
of approx. 65 °C.
The electrical mode of operation is activated using the operating switch
(Fig. 159). The indicator lamp (Fig. 159,1) on the switch must illuminate.
During hot air operation, the water in the hot water source is heated up by the
heater and the circulating air.
Depending on the model, the vehicle is fitted with one or two hot water source
drain cocks.
Z
Do not fit a check valve in the cold water pipe between the hot water source
and the water pump.
Z
Use a pressure reducer when connecting to a central water supply or with
strong pumps. The hot water source is designed only for pressures of up
to 1.2 bar. In addition, insert a safety/drainage valve in to the cold water
pipe.
Z
Do not use the water from the hot water source as drinking water.
Fig. 159 Operating switch for hot water
source
Summary of Contents for Averso
Page 2: ...Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Instruction manual ...
Page 10: ...10 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Introduction 1 ...
Page 34: ...34 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Before the journey 3 ...
Page 90: ...90 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Gas system 7 ...
Page 152: ...152 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Sanitary fittings 10 ...
Page 164: ...164 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Care 11 ...
Page 224: ...Index 224 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN ...