![background image](http://html1.mh-extra.com/html/burstner/averso/averso_instruction-manual_2833262123.webp)
123
Premio/Averso - 13/14 - Ausgabe 09/13 - 2354619 - BUE-0048-12EN
Appliances
9
230 V electrical operation
The boiler is operated exclusively with electricity.
Switching on:
Connect the vehicle to the external 230 V power supply and switch on the
230 V automatic circuit breaker.
Set flip switch (Fig. 157,1) to on. The indicator lamp on the switch is illumi-
nated. The water in the boiler is heated up to 65 °C.
Switching off:
Set the flip switch (Fig. 157,1) to " ". The indicator lamp on the switch goes
off.
Combined operation
The water is heated more quickly in the boiler if gas operation and 230 V elec-
trical operation are switched on simultaneously.
Filling/emptying the boiler
The boiler can be supplied with water from the water tank.
Depending on the model, the vehicle is fitted with one or several boiler drain
cocks. The drain cocks can have different designs (rocking lever or twist cap).
Filling the boiler with water:
Close all boiler drain cocks. To do this, position the rocking lever
(Fig. 158,1) horizontally or turn the cap (Fig. 158,2) in a clockwise direc-
tion.
Set all the water taps to "Hot" and open them. The water pump is turned
on. The warm water pipes are filled with water.
Z
230 V electrical operation is only possible when the vehicle is connected to
the 230 V power supply.
Fig. 157 Flip switch for Truma boiler
(230 V electrical operation)
Z
Further information can be obtained in the manufacturer's instruction
manual.
Fig. 158 Drain cocks
Summary of Contents for Averso
Page 2: ...Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Instruction manual ...
Page 10: ...10 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Introduction 1 ...
Page 34: ...34 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Before the journey 3 ...
Page 90: ...90 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Gas system 7 ...
Page 152: ...152 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Sanitary fittings 10 ...
Page 164: ...164 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Care 11 ...
Page 224: ...Index 224 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN ...