![background image](http://html1.mh-extra.com/html/burstner/averso/averso_instruction-manual_2833262115.webp)
115
Premio/Averso - 13/14 - Ausgabe 09/13 - 2354619 - BUE-0048-12EN
Appliances
9
9.2.6
Warming unit for waste water pipes (special equipment)
In order to prevent waste water pipes freezing up, the waste water pipes can
be electrically warmed.
When the warming unit is turned on, the temperature of the waste water pipes
is monitored by temperature sensors. If the temperature falls below 5 °C, the
heating elements are switched on and the waste water pipes are warmed. If
the temperature rises above 7 °C, the heating elements are switched off
again.
The 230 V AC/12 V DC transformer (Fig. 147,2) is installed in the wardrobe or
in the storage area beneath the seating group, depending on the model.
The control unit is integrated in the transformer housing. The control lamps
have the following meanings:
z
Indicator lamp (Fig. 147,5) lights up in green: Regulation in operation
z
Indicator lamps (Fig. 147,4 and 6) light up in red: Waste water pipes are
warmed
A test button (Fig. 147,3) is integrated in the housing with which the control
unit can be operated for a short time. By pressing the test button, the function
of the warming unit can be tested, even if the ambient temperature is above
5 °C.
Switching on:
Connect the vehicle to a 230 V power supply (see section 8.5.1).
Turn switch (Fig. 147,1) on the transformer (Fig. 147,2) to "ON".
Switching off:
Turn switch (Fig. 147,1) on the transformer (Fig. 147,2) to "OFF".
Z
Always only press the test button briefly.
Z
The warming unit only functions when the vehicle is connected to a 230 V
power supply.
Fig. 147 Transformer with control unit
Summary of Contents for Averso
Page 2: ...Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Instruction manual ...
Page 10: ...10 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Introduction 1 ...
Page 34: ...34 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Before the journey 3 ...
Page 90: ...90 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Gas system 7 ...
Page 152: ...152 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Sanitary fittings 10 ...
Page 164: ...164 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN Care 11 ...
Page 224: ...Index 224 Premio Averso 13 14 Ausgabe 09 13 2354619 BUE 0048 12EN ...