RM1250 User Guide
5
Wiring Requirements
: For optimum protection from transient voltages, all analog inputs must be in
their own multi-conductor jacket cable (such as cable AI part number 211061-000 - Belden 5308UE, or
its equivalent). All cables must have intact outer jackets, except for end cuts. Do not remove cable
jackets as they protect the unit input cable from transient voltages. Cable insulation should be suited
for voltage range of inputs. Cables should be rated at a minimum of 600 V and 105
˚
C.
Input Channel Voltage Levels
: All input channels are marked with acceptable input voltage ranges.
Ensure that devices connected to the RM1250 units fall within the voltages ranges listed next to the
channel input connections.
Mounting the Enclosure
: Choose an area that provides enough room to easily access the unit or to
perform routine maintenance after completing the installation.
W
ARNING
:
Only accessories that meet American Innovations specifications may be used with the RM1250.
Refer to
Technical Specifications
for a list of accessories and requirements.
Required Tools and Equipment
The following tools and equipment are required for installing and configuring the unit for service:
•
Magnet
•
Anti-static wrist strap
•
Small slotted screwdriver
•
Wire stripper / Wire cutter
•
Installation drawing (provided)
•
Index or index adapter, if needed
Required Hardware and Software
To configure a unit in the field, you will need either of the following:
•
A computer running Microsoft
®
Windows
®
with the following hardware and software specifications
(refer to
Configuration and Support Software
):
–
Pentium
®
processor or equivalent
–
2 GB RAM (minimum)
–
400 MB free hard drive space (minimum)
–
Spare USB port