RM1250 User Guide
11
After installation, the RM1250 can be configured with the Bullhorn Tools configuration software on a laptop or
with the mobile application on a smartphone or tablet. Bullhorn Tools can display reading, set up transmission
schedules, set alarms, send a test message, or send an email to Technical Services. Refer to
Configuration
for
more information on using Bullhorn Tools.
N
OTE
:
Because of the variations in customer's installation and grounding methods, AI cannot warranty any
damage to equipment caused by lightning strikes.
Preparing for Installation
W
ARNING
:
Only accessories that meet American Innovations specifications may be used with the RM1250.
Refer to
Technical Specifications
for a list of approved accessories.
Use the following items as a checklist prior to installing the RM1250:
1
For information regarding safety symbols found on the unit, refer to
Safety and Equipment Symbols
.
2
Ensure that the latest version of Bullhorn Tools and other support software are installed on the computer
or device that you plan to use to configure the unit. Bullhorn Tools can be downloaded from the Bullhorn
Web Help (
Downloads
) page, andBullhorn Tools Mobile can be downloaded from the Apple App Store.
For more information, refer to
Installation
.
Electrostatic Discharge
Electrostatic Discharge (ESD) can damage electronic components. Provide ESD protection by wearing an anti-
static wrist strap attached to any unpainted metal surface
before
making contact with any internal components.
If an anti-static wrist strap is unavailable, discharge static electricity from yourself and your clothing by touching
a nearby metal surface before opening the enclosure door of the unit or handling electronic components.
Installing Conduit
I
MPORTANT
:
If wires are to be buried or covered, use conduit to protect wires.
Install and dress conduit to protect wiring from physical damage, electrical interference, or weather. Conduit is
provided by the customer.