RM1250 User Guide
25
3
To disable a reading, select
Disabled
.
4
Click
Save
to save settings or
Cancel
to clear all fields.
Configure Readings
Complete the following steps to configure the enabled Readings:
1
Click the name of the Reading under
Readings.
N
OTE
:
Only enabled Readings display in the list.
2
For accumulators, complete the following configuration steps in the
Accumulator
pane:
Figure 3-10. Accumulator Settings
a
Enter a quantity represented by one input pulse in the
Units Per Pulse
field.
b
Select a value from the list in the
First
Sensor Index To Register
field that indicates the significant
digits used when scaling.
c
Enter a value for the accumulator in the
Accumulator Value
field.
N
OTE
:
The
Meter Factor
field is a calculated value based on
Units Per Pulse
and
First Sensor Index to
Register
fields. This value is updated when either of these fields change. The
Sensor Equivalent
displays the actual index odometer reading and is display only.
d
Click
Save
to save settings or
Cancel
to clear all fields.