RM1250 User Guide
13
Installing the RM1250
I
MPORTANT
:
Electrostatic Discharge (ESD) can damage electronic components. Provide ESD protection by
wearing an anti-static wrist strap attached to any unpainted metal surface before accessing the unit or handling
electronic parts. If an anti-static wrist strap is unavailable, discharge static electricity from yourself and your
clothing by touching a nearby metal surface before accessing the unit or handling electronic components.
The following section explains how to install the RM1250 with the flat base. For alternative installation options,
please contact Technical Services ([email protected]).
N
OTE
:
To ensure a clean stable reading, keep field wiring as short as possible and use shielded twisted pair wire
such as Alpha 2463C. American Innovations recommends using AI part number 211061-000 (Belden 5308UE), or
equivalent, for wiring inputs.
Complete the following steps to install the RM1250:
1
Attach the flat base to a mounting bracket (either an existing bracket or the optional adjustable bracket).
Figure 2-4. RM1250 Flat Base and Adjustable Mounting Bracket (optional)
2
If necessary, mount assembly to a structure, such as a pole, which is near the external device.
3
Bring the wires connecting the external device up through the bottom of the flat base.
4
Connect the external device to the 4-pin terminal.
5
Connect the 4-pin terminal to the corresponding connection on the RM1250.