The PXE boot (network boot) fails or the system is not found on the network:
■
Is the cable connected properly?
- Connect the proper cable to the network port on the rear of the Express server.
In addition, make sure that the used cable conforms to the network interface
standard.
■
Is BIOS configuration correct?
- The internal LAN controller may be disabled with the CMOS Setup utility of
the system. Check the setting with the BIOS setup utility.
■
Have the protocol and service already configured?
- Install the distinctive network driver for the system. Make sure that the proto-
col, such as TCP/IP, and services are properly specified.
■
Is the transfer speed correct?
- Open the network property dialog box in control panel to specify the link speed
and duplex value the same as the value specified for HUB.
Problems with ExpressBuilder
When the system does not boot from the ExpressBuilder disc, check the following:
■
Did you set the ExpressBuilder during POST and restart the system?
- If you do not set the ExpressBuilder during POST and restart the system, an
error message will appear or the OS will boot.
■
Is BIOS configuration correct?
- The boot device order may be specified with the CMOS Setup utility of the sys-
tem. Use the CMOS Setup utility to change the boot device order to boot the
system from the disc drive first.
<Menu to check: [Boot]>
■
Has an error message appeared?
- When an error occurs while the ExpressBuilder is in progress, the following
message appears. After this message appears, check the error and take the
appropriate corrective action according to the message listed in the table below.
Table 6: Error Messages
Message
Cause and Solution
This machine is not supported
This ExpressBuilder version is not designed for
this system. Execute the ExpressBuilder on the
compliant system.
Hard disk access error
The hard disk is not connected or has failed.
Check whether the hard disk is correctly
connected.
Summary of Contents for NovaScale T840 E2
Page 1: ...NovaScale T840 E2 User s Guide NOVASCALE REFERENCE 86 A1 43FB 01 ...
Page 2: ......
Page 34: ...User Guide 34 www bull com ...
Page 58: ...User Guide 58 www bull com 3 5 HDD cover 3 metric screws M4 Figure 16 Securing the HDD cover ...
Page 112: ...User Guide 112 www bull com Refer to Advanced Menu on page 174 for more information ...
Page 130: ...User Guide 130 www bull com The installation is completed ...
Page 134: ...User Guide 134 www bull com Installing the Operating System without Express Setup ...
Page 169: ...User Guide 169 www bull com Figure 76 Diagnostic LED POST Code Decoder continued ...
Page 209: ......
Page 210: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 43FB 01 ...